POWER QUALITY ANALYZER 3197

3197

Call 02 9150 7744 For the BEST DEAL

POWER QUALITY ANALYZER 3197

The most comprehensive portable PQA on the market
Catch power quality problems on the fly, before they catch you!
  • Monitor for : Inrush current, Voltage swell, Voltage dips, Transient over-voltage, Interruptions
  • Measure and record : Power and Power factor, Active/Reactive energy, Demand, Load changes (with graph display), Voltage and current
Note: Optional current sensor is necessary to measure current or power parameters.
Basic specifications (Accuracy guaranteed for 1 year)
Measurement line type Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, three-phase 4-wire
Voltage range 600.0 V AC
Current ranges 500.0 mA to 5.000 kA AC (depends on current sensor in use)
Power ranges 300.0 W to 9.00 MW (depends on combination of current range and line type)
Basic accuracy Voltage: ±0.3 % rdg. ±0.2 % f.s.
Current: ±0.3 % rdg. ±0.2 % f.s. + current sensor accuracy
Active power: ±0.3 % rdg. ±0.2 % f.s. + current sensor accuracy (at power factor=1)
Measurement items
  1. RMS Voltage and Current (200 ms calculation)
  2. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle.
  3. Current (1/2) RMS: half-cycle calculation.
  4. Frequency
  5. Active Power/ Reactive Power/ Apparent Power/ Power Factor/ Displacement Power Factor/ Active or Reactive Energy Consumption
  6. Demand (Active or Reactive power)
  7. Up to 50th Harmonic Analysis (Time series measurement or recording is not capable)
  8. Peak Voltage and Current
  9. Total harmonic voltage distortion ratio
  10. Voltage Unbalance Factor
  11. K Factor (Time series recording is not capable)
  12. Total harmonic current distortion ratio (Time series recording is not capable)
Event Detection
  1. Voltage Swells (Rise), Voltage Dips (Drop), Interruptions: RMS value detected using voltage (1/2) measured every half cycle
  2. Inrush Current: RMS value detected using current (1/2) every half cycle
  3. Transient Overvoltage: 50 Vrms or more detection, 10 to 100 kHz
  4. Timer: Detect events at preset intervals
  5. Manual: Detect events when keys are pressed
Number of Recordable Events 50 event waveforms, 20 event voltage fluctuation graphs, 1 inrush current graph, 1000 event counts
Interface USB 2.0 (Communication to the PC)
Display 4.7-inch color STN LCD
Power supply AC ADAPTER 9418-15 (100 - 240V, 50/60Hz), BATTERY PACK 9459, Continuous use 6 hours (LCD Back-light auto-OFF 5min.), 23VA max.
Dimensions, mass 128 mm (5.04 in) W × 246 mm (9.69 in) H × 63 mm (2.48 in) D, 1.2 kg (42.3 oz) (with Battery pack)
Supplied accessories VOLTAGE CORD L9438-55 ×1 (Black×4), AC ADAPTER 9418-15 ×1, BATTERY PACK 9459 ×1, USB Cable ×1, Input Terminal Labels ×1, Input Cord Labels ×1, CD-R (Applications software) ×1, Strap ×1, Carrying case ×1, Measurement guide ×1, Instruction manual ×1

3197 (3197E8-14B-03K_A4.pdf, 6,441 Kb) [Download]

Good to know