SCHNAP Logo

Making Trade Life Easy!
Trade Discount 25%

10kVA 10kW Online UPS 20x 80Ah Battery Bank Tower Enduro

BRAND: CABAC
SKU: EN10-80-20-T-LL
$19,562.40 List price: $26,083.20
Free pick up (over 25 kg or over 1 meter)
Contact us for delivery cost
Enduro 10kVA 10kW online double conversion UPS features 20x 80ah battery bank, 10 year design life batteries and onsite cabinet assembly. Ideal for servers.

Alternatively Known As: ENDURO Long-Run Online UPS, ENDURO 10kVA Tower UPS, 10kW Server UPS, EN10-80-20-T-LL

Technical Specifications
  • Rated Capacity: 10kVA / 10kW
  • Topology: Online double conversion
  • Output Waveform: Pure sinewave
  • Configuration: 1:1 single phase
  • Mounting: Tower or rack/tower UPS control unit; floor-standing battery bank
  • Battery Bank: 20 x 12V 80Ah sealed lead-acid batteries
  • Battery Design Life: 10 years
  • Input Voltage: 230V ±20%
  • Input Frequency Range: 45–65Hz
  • Output Voltage: 230V ±2%
  • Output Frequency: 50Hz ±0.1Hz in battery mode
  • Input Power Factor: ≥0.98
  • Output Power Factor: 1.0
  • Efficiency: 89–92% normal mode; up to 97% ECO mode
  • Communications: USB and RS-232 standard; optional SNMP and relay card
  • Protection: Resettable circuit breaker, overload, short-circuit, battery and temperature protection
  • Monitoring: Interactive LCD display and smart management software
  • Runtime Expansion: External battery modules and long-run battery cabinet
  • Noise Level: Less than 50dB at 1m
  • Operating Temperature: 0–40°C
  • Installation Note: Battery cabinet requires onsite assembly
  • UPS Control Unit Dimensions: 443 x 580 x 217mm; 5RU
  • Estimated Complete System Weight: Approximately 620kg, including UPS, 20-battery bank and cabinet
  • Dimensions (H x L x W): 1520mm x 780mm x 470mm
  • Weight: 620 kg
Key Features
  • True online double-conversion power protection for servers and sensitive IT equipment
  • 10kVA capacity with 10kW unity power factor output
  • 20 x 80Ah sealed lead-acid battery bank for extended runtime
  • 10-year design-life batteries supplied as part of the long-run configuration
  • Pure sinewave output suitable for servers, networking and industrial electronics
  • Generator-compatible operation
  • Interactive LCD status display and intelligent battery charging
  • Emergency Power Off (EPO) function
  • Optional SNMP and relay communications for remote monitoring
  • Floor-standing battery cabinet supplied for onsite assembly
Professional Installation Requirements
  • Professional installation is required. The UPS uses hardwired mains input and output connections and a high-capacity external battery bank. Installation, battery cabinet assembly, commissioning and electrical connection should be completed by a licensed electrician or suitably qualified critical-power contractor in accordance with AS/NZS 3000, the manufacturer’s installation instructions and applicable workplace safety requirements.
Applications
  • Server rooms and data centres
  • Telecommunications and network infrastructure
  • Industrial control and automation systems
  • Security, surveillance and access-control systems
  • Medical and other critical electronic equipment
  • Sites requiring extended backup runtime or generator compatibility
Standards & Compliance
  • AS IEC 62040.1: Uninterruptible power systems — general and safety requirements
  • AS IEC 62040.2: Uninterruptible power systems — electromagnetic compatibility requirements
  • AS IEC 62040.3: Uninterruptible power systems — method of specifying performance and test requirements
  • AS/NZS 3000: Electrical installations — Wiring Rules, applicable to permanent UPS installation and connection
Environmental Benefits
  • Sealed lead-acid batteries are recoverable through established battery recycling streams when replaced
  • 10-year design-life batteries can reduce replacement frequency and associated material waste compared with shorter-life battery options
  • Online power conditioning can protect connected equipment from voltage and frequency disturbances, helping reduce premature equipment failure
  • High-efficiency ECO operation can reduce energy losses during suitable operating conditions
  • Replaceable battery-bank architecture allows the UPS electronics and cabinet to remain in service when batteries are renewed
Warranty Information

PSA/PSS warranty terms apply to manufacturing defects, with repair or replacement at the supplier’s discretion. The applicable warranty period should be confirmed against the individual UPS user manual or quotation; removal, reinstallation, labour and transport costs may be excluded. Australian Consumer Law rights also apply.

Available Now

Available through ENDURO/PSS and authorised Australian distributors. This configured long-run system is generally supplied by quotation and requires onsite battery cabinet assembly.


UPS Sizing Calculator




This calculator follows relevant Australian standards to ensure reliable and compliant performance. It provides an estimated recommendation based on user inputs.
Users must verify specifications before purchasing.