3kVA 2.7kW Online UPS 2 Battery Banks Rack Tower Enduro
Enduro 3kVA 2.7kW online double conversion UPS features 2 battery banks and rack or tower mounting. Ideal for servers and sensitive IT loads.
Sign in
Please login to continue to your account.
Alternatively Known As: ENDURO EN3000 UPS, 3kVA Online UPS, 2700W Rack/Tower UPS, Pure Sinewave UPS
- Model: EN3000
- Capacity: 3kVA / 2.7kW
- Topology: Online double conversion
- Phase: Single-phase input and single-phase output
- Input Voltage: 230V ±20%
- Input Frequency: 45–65Hz
- Output Voltage: 230V AC ±2%
- Output Frequency in Battery Mode: 50Hz ±0.1Hz
- Output Power Factor: 0.9
- Waveform: Pure sinewave
- Battery Type: Sealed lead-acid, maintenance-free VRLA
- Standard Battery Configuration: 6 x 12V 9Ah batteries
- Rated Battery Voltage: 72V
- Battery Banks: Two battery banks as specified for this configuration
- Recharge Time: Approximately 5 hours to 90% capacity
- Output Connections: 3 x Australian 3-pin sockets, including critical and non-critical outlets
- Communications: USB and RS-232 standard; optional SNMP and relay card
- Protection: Overload, short circuit, resettable circuit breaker, surge protection and emergency power off
- Mounting: 19-inch rack or tower configuration
- Operating Temperature: 0°C to 40°C
- Relative Humidity: 0–95% non-condensing
- Noise Level: Less than 50dB at 1m
- Efficiency: Approximately 89% in normal mode; up to 97% in ECO mode
- Data source: ENDURO EN3000 specification and user manual; dimensions and battery data refer to the UPS chassis, excluding external battery-bank cabinets. ([manuals.plus](https://manuals.plus/enduro/1-3kva-pure-sinewave-on-line-ups-manual))
- Dimensions (H x L x W): 86.5mm x 600mm x 440mm
- Weight: 26.8 kg
- Online double-conversion topology for continuous power conditioning
- Pure sinewave output for servers, networking equipment and other sensitive IT loads
- 3kVA / 2.7kW capacity for small server rooms and critical infrastructure
- Two battery banks for extended backup runtime
- Rack or tower mounting flexibility
- Interactive LCD screen for operating, load and battery status
- USB and RS-232 communications for monitoring and controlled shutdown
- Optional SNMP and relay communications
- Emergency power off function
- Generator-compatible design
- Expandable runtime architecture using external battery modules
- Installation, commissioning and battery-bank connection should be completed by suitably qualified electrical or UPS personnel in accordance with the manufacturer's instructions and applicable Australian electrical requirements. Permanent electrical work should comply with AS/NZS 3000. Battery servicing must be performed by trained personnel because hazardous voltages and lead-acid batteries are present. ([manuals.plus](https://manuals.plus/enduro/1-3kva-pure-sinewave-on-line-ups-manual))
- Server rooms and data racks
- Network switches, routers and telecommunications equipment
- Point-of-sale and business-critical systems
- Security, surveillance and access-control systems
- Industrial control and monitoring equipment
- Sensitive IT loads requiring uninterrupted, conditioned power
- AS 62040.1:2019 – applicable Australian safety standard for uninterruptible power systems; product-specific conformity documentation should be confirmed for the supplied unit. ([eess.gov.au](https://www.eess.gov.au/wp-content/uploads/2020/07/20-006-General-guidance-Standards-for-portable-UPS-devices-1.pdf?utm_source=openai))
- AS/NZS 3000:2018 – applicable to permanent electrical installation, isolation, earthing and connection work; this is an installation requirement rather than a product certification claim. ([ups.services](https://ups.services/standards?utm_source=openai))
- Online power conditioning can help protect connected equipment and reduce premature replacement caused by voltage disturbances
- ECO mode can improve operating efficiency when the highest level of conditioning is not required
- Sealed lead-acid batteries can be recovered through appropriate battery recycling programmes
- Rack/tower flexibility and replaceable battery architecture can extend the usable service life of the UPS and reduce electronic waste
- Battery disposal and recycling should be managed through approved Australian battery-recycling channels
PSS Distributors publishes a standard 2-year return-to-base warranty from the original purchase date for PSS products, subject to proof of purchase, correct installation, operation within specified conditions and the published exclusions. Confirm coverage for the supplied ENDURO configuration and battery banks at purchase. ([pssdistributors.com.au](https://www.pssdistributors.com.au/ups-warranty/?utm_source=openai))
Available through ENDURO/PSS Distributors and authorised Australian distributors; live stock and configuration availability should be confirmed before ordering. ([pssdistributors.com.au](https://www.pssdistributors.com.au/p/power-supplies-batteries/uninterruptible-power-supplies/on-line-ups/en3lr-120-12?utm_source=openai))
UPS Sizing Calculator
This calculator follows relevant Australian standards to ensure reliable and compliant performance. It provides an estimated recommendation based on user inputs.
Users must verify specifications before purchasing.