ATS 3P 100A High Breaking Type A 125A Frame NXZM Chint
Chint NXZM 100A 3P ATS features CB class changeover, Type A standard controller, high breaking capacity and 125A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM 100A ATS, 3P Automatic Changeover Switch, Mains-Generator Transfer Switch, Class CB ATS
- Model: NXZM-125H/3A 100A
- Product Type: Automatic transfer switching equipment
- Transfer Class: Class CB, circuit-breaker based
- Number of Poles: 3P
- Rated Current: 100A
- Frame Current: 125A
- High-Breaking Capacity: 50kA rated short-circuit breaking capacity
- Rated Short-Circuit Making Capacity: 105kA
- Rated Operational Voltage: 400/415V AC, 50Hz
- Rated Insulation Voltage: 800V AC
- Rated Impulse Withstand Voltage: 8kV
- Utilisation Category: AC-33B
- Controller: Type A standard controller
- Control Supply: 230/240V AC, 50Hz
- Control Voltage Range: 85% to 110% of rated voltage
- Operating Transfer Time: Approximately 2.8 seconds
- Mechanical Endurance: 10,000 operations
- Electrical Endurance: 2,000 operations
- Installation: Integrated or split installation options
- Dimensions (H x L x W): 240mm x 312mm x 190mm
- Weight: 3.5 kg
- Automatic changeover between mains and generator supplies
- High-breaking H type configuration for higher fault-current capability
- 100A switching capacity within a 125A frame
- Three-pole circuit-breaker-based transfer arrangement
- Built-in Type A standard controller
- Manual operation capability for emergency or maintenance use
- Suitable for commercial, industrial and residential backup-power systems
- Designed for 400/415V AC three-phase power systems
- Installation, commissioning and connection to mains or generator supplies must be completed by a licensed electrician in accordance with AS/NZS 3000, AS/NZS 3010 and the equipment instructions. Verify neutral switching, generator earthing, fault levels and required local electrical approvals before energisation.
- Mains-generator automatic changeover
- Standby generator installations
- Commercial and industrial power distribution
- Residential backup-power systems
- High-rise building emergency power systems
- Critical-load transfer between two three-phase supplies
- Applicable transfer-switch equipment standard: AS/NZS IEC 60947.6.1:2015
- Electrical installation and generator connection requirements should be assessed against AS/NZS 3000 and AS/NZS 3010:2017
- Long service life and high operating endurance can reduce replacement frequency and electrical equipment waste
- Metallic electrical components are generally recoverable through established electrical equipment recycling streams
- Supports continuity of supply for efficient operation of connected electrical equipment
CHINT warranty policy specifies 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, unless a different period is stated in the sales contract.
Available through authorised CHINT distributors in Australia.