ATS 3P 125A Type A 125A Frame NXZM Chint
Chint NXZM 125A 3P ATS features CB class changeover, Type A standard controller and 125A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM 125A 3P ATS, Automatic Changeover Switch, Mains-Generator Transfer Switch
- Product Series: NXZM
- Configuration: 3-pole, 3-phase
- Frame Current: 125 A
- Rated Current: 125 A
- Controller: Type A standard controller
- Transfer Class: CB class
- Rated Operational Voltage: 400/415 V AC, 50 Hz
- Rated Control Supply: 230 V AC, 50 Hz
- Control Voltage Range: 85–110% of rated voltage
- Utilisation Category: AC-33B
- Rated Insulation Voltage: 500 V AC
- Rated Impulse Withstand Voltage: 4 kV
- Rated Short-Circuit Making Capacity: 9.18 kA
- Rated Short-Circuit Breaking Capacity: 6 kA
- Mechanical Endurance: 10,000 operations
- Electrical Endurance: 3,000 operations
- Typical Operating Transfer Time: 1.4 seconds
- Installation: Integrated controller, suitable for vertical or horizontal mounting
- Enclosure Protection: IP20
- Operating Temperature: -5°C to +40°C
- Dimensions (H x L x W): 300mm x 240mm x 178mm
- Weight: 1.5 kg
- Automatic transfer between normal mains and alternate generator supplies
- Three-pole changeover for three-phase power systems
- CB class transfer switching equipment
- Type A standard controller for automatic monitoring and switching
- 125 A frame and 125 A rated current
- Suitable for mains-generator changeover applications
- Manual and automatic operating modes
- Designed for industrial, commercial and building power systems
- Installation, commissioning and maintenance must be performed by a licensed electrician in accordance with manufacturer instructions, AS/NZS 3000 and the applicable transfer-switch requirements of AS/NZS IEC 60947.6.1.
- Mains-generator automatic changeover
- Three-phase standby power systems
- Commercial buildings and industrial facilities
- Residential and high-rise building backup power systems
- Critical load power distribution and emergency supply systems
- AS/NZS IEC 60947.6.1:2015 for low-voltage transfer switching equipment
- AS/NZS 3000 for electrical installation and wiring requirements
- Durable switchgear construction can reduce replacement frequency and associated waste
- Metal switchgear components are suitable for recovery and recycling at end of service life
- Supports generator integration and controlled transfer of standby power without unnecessary manual intervention
CHINT general warranty policy covers other low-voltage apparatus against defects in materials and workmanship for 27 months from the date of manufacture; local contractual and authorised-distributor conditions may apply.
Available through authorised CHINT distributors in Australia.