ATS 3P 160A High Breaking Type A 250A Frame NXZM Chint
Chint NXZM 160A 3P ATS features CB class changeover, Type A standard controller, high breaking capacity and 250A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM 160A ATS, 3P Automatic Changeover Switch, Mains-Generator Transfer Switch, Class CB ATS
- Rated Current: 160 A
- Frame Current: 250 A
- Number of Poles: 3P
- Switching Class: Class CB
- Controller: Type A standard controller
- Rated Operational Voltage: 400/415 V AC, 50 Hz
- Rated Insulation Voltage: 1,000 V AC
- Rated Short-Circuit Breaking Capacity: 50 kA
- Rated Short-Circuit Making Capacity: 105 kA
- Utilisation Category: AC-33B
- Operating Transfer Time: Approximately 3.3 seconds
- Rated Control Supply: 230/240 V AC, 50 Hz
- Control Voltage Range: 85% to 110% of rated voltage
- Mechanical Endurance: 6,000 operations
- Electrical Endurance: 2,000 operations
- Enclosure Protection: IP20
- Installation Category: III
- Pollution Degree: 3
- Maximum Recommended Altitude: 2,000 m
- Dimensions (H x L x W): 393mm x 357mm x 225mm
- Weight: 0.9 kg
- High breaking capacity H-class configuration
- Class CB automatic transfer construction using circuit breakers
- Three-pole switching for three-phase power systems
- Type A standard controller with automatic source monitoring
- Suitable for mains-generator and grid-grid changeover applications
- Automatic transfer and restoration between normal and alternative power sources
- Manual and automatic operating modes
- Mechanical interlocking to help prevent simultaneous source connection
- Padlockable off position for maintenance isolation
- Installation, commissioning and maintenance must be carried out by a licensed electrical contractor. The unit must be correctly integrated into the switchboard and generator system in accordance with the manufacturer's instructions and applicable Australian wiring and generating-set requirements.
- Mains-generator automatic changeover
- Three-phase standby power systems
- Commercial and industrial switchboards
- Critical power and emergency supply systems
- Grid-grid source transfer installations
- High-rise, infrastructure and facility power distribution
- AS/NZS IEC 60947.6.1:2015 — transfer switching equipment
- AS/NZS 3010:2017 — generating-set installations where used in a generator changeover system
- AS/NZS 3000 — electrical installations and wiring rules for the completed installation
- Supports continuity of supply and efficient use of standby generation by automatically transferring loads between available power sources
- Durable moulded-case switchgear construction can support extended service life and reduce replacement waste
- Metal and thermoplastic switchgear components can be separated for appropriate recycling at end of service life
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised sales channels, subject to the applicable contract terms and exclusions.
Available through authorised CHINT distributors in Australia.