Alternatively Known As: CHINT NXZM 160A ATS, 3P Automatic Changeover Switch, Mains-Generator Transfer Switch
- Product Type: Automatic transfer switching equipment
- Switching Class: CB class
- Number of Poles: 3P
- Frame Current: 160A
- Rated Operational Current: 160A
- Rated Operational Voltage: 400/415V AC
- Rated Frequency: 50/60Hz
- Utilisation Category: AC-33B
- Rated Insulation Voltage: 800V AC
- Rated Impulse Withstand Voltage: 8kV
- Controller: Type A standard controller
- Controller Supply: 230/240V AC, 50Hz
- Control Voltage Range: 85% to 110% of rated operational voltage
- Installation: Integrated or split controller installation
- Ingress Protection: IP20
- Operating Temperature: -5°C to +40°C
- Transfer Time: Approximately 3.3 seconds for the NXZM-160 frame, subject to configuration
- Standard Product Testing: IEC/EN 60947-6-1 automatic transfer switching equipment requirements
- Dimensions (H x L x W): 195mm x 345mm x 250mm
- Weight: 8 kg
- Automatic changeover between normal mains and standby generator supplies
- 3-pole switching configuration for three-phase systems
- 160A frame and rated current suitable for higher-load standby power applications
- CB class construction using circuit-breaker-based switching devices
- Type A standard controller for automatic voltage monitoring and transfer control
- Manual operating capability for testing, isolation and maintenance
- Suitable for integrated or door-mounted split-controller installation
- Designed for mains-generator changeover and emergency power systems
- Installation, wiring, commissioning and testing must be performed by a licensed electrician in accordance with AS/NZS 3000 and, where used with a generating set, AS/NZS 3010. The ATS must be correctly coordinated with the switchboard, generator protection, earthing system and available fault level.
- Mains-generator automatic changeover
- Standby power systems
- Commercial and industrial switchboards
- Emergency power supplies
- Telecommunications and critical infrastructure power systems
- Three-phase distribution and generator installations
- AS/NZS 3000:2018 for electrical installation and switchboard wiring requirements
- AS/NZS 3010:2017 for electrical installations incorporating generating sets
- AS/NZS 61439.1 and AS/NZS 61439.2 for low-voltage switchboard assemblies rated 125A per phase or greater
- Durable switchgear construction can extend service life and reduce replacement waste
- Metal components such as copper and aluminium are recyclable at end of service life
- Supports efficient standby power management by automatically transferring loads only when required
- Repairable and serviceable switchgear design can reduce whole-unit replacement frequency
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, unless a different period is specified in the sales contract. Warranty coverage is subject to correct installation, operation and maintenance.
Available through authorised CHINT distributors in Australia.