- Product Type: Automatic transfer switching equipment
- Configuration: 3-pole, class CB changeover
- Frame Current: 250 A
- Rated Operational Current: 250 A
- Breaking Capacity: High type, 50 kA rated short-circuit breaking capacity
- Rated Short-Circuit Making Capacity: 105 kA
- Rated Operational Voltage: 400/415 V AC
- Rated Insulation Voltage: 1000 V AC
- Rated Impulse Withstand Voltage: 8 kV
- Utilisation Category: AC-33B
- Controller: Type A standard controller
- Control Supply: 230/240 V AC, 50 Hz
- Control Voltage Range: 85% to 110% of rated operational voltage
- Operating Transfer Time: 3.3 seconds, ±10%
- Mechanical Endurance: 6000 operations
- Electrical Endurance: 2000 operations
- Ingress Protection: IP20
- Installation: Integrated or split installation options
- Dimensions (H x L x W): 216mm x 393mm x 250mm
- Weight: 12 kg
- Automatic transfer between normal mains and standby generator supplies
- Three-pole switching for three-phase power systems
- Class CB design incorporates circuit-breaker switching elements
- High H-type short-circuit performance with 50 kA breaking capacity
- 250 A frame and 250 A rated operational current
- Type A standard controller for essential voltage monitoring and automatic changeover
- Suitable for mains-generator changeover applications
- Manual operation and reset capability for commissioning and maintenance
- Installation, commissioning and testing must be performed by a licensed electrician in accordance with applicable electrical installation, switchboard and generating-set requirements. Verify neutral switching, protection coordination, fault levels and generator interlocking before energisation.
- Mains-to-generator automatic changeover
- Standby power systems
- Commercial and industrial switchboards
- Emergency power distribution
- Three-phase building services and critical loads
- Applicable product standard: AS/NZS IEC 60947.6.1 for transfer switching equipment
- Installation with generating sets should comply with AS/NZS 3010 and applicable requirements of AS/NZS 3000
- Durable switchgear construction can support a long service life and reduce replacement waste
- Metallic electrical components are generally recyclable at end of service life
- Automatic transfer operation supports continuity of supply for efficient standby-power management
- Suitable for generator systems that can reduce reliance on grid supply during outages or peak-demand periods
CHINT warranty policy for other low-voltage apparatus provides 27 months from the date of manufacture when sold through authorised channels; contractual terms may vary.
Available through authorised CHINT distributors in Australia.