ATS 3P 315A Type A 400A Frame NXZM Chint
Chint NXZM 315A 3P ATS features CB class changeover, Type A standard controller and 400A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM 315A ATS, 315A Automatic Changeover Switch, Mains-Generator Changeover Switch, CB-Class ATSE
- Device Type: Circuit-breaker class automatic transfer switching equipment
- Rated Current: 315 A
- Frame Current: 400 A
- Number of Poles: 3P
- Rated Operational Voltage: 400/415 V AC
- Rated Frequency: 50 Hz
- Utilisation Category: AC-33B
- Controller: Type A standard controller
- Control Supply Voltage: 230/240 V AC, 50 Hz
- Operating Transfer Time: Approximately 3.5 seconds
- Installation Mode: Integrated or split controller installation
- Mechanical Endurance: Up to 4,000 operations
- Electrical Endurance: Up to 1,500 operations
- Environmental Operating Range: -25°C to +70°C with manufacturer provisions
- Maximum Installation Altitude: 2,000 m without derating
- Dimensions (H x L x W): 535mm x 475mm x 304mm
- Weight: 30 kg
- Automatic transfer between mains and generator supplies
- CB-class changeover arrangement with circuit-breaker protection
- Three-pole switching for three-phase applications
- 400 A frame size with 315 A rated current
- Type A standard controller with automatic monitoring and transfer functions
- Manual, automatic and off operating modes
- Mechanical interlocking helps prevent simultaneous connection of both sources
- Suitable for grid-generator and grid-grid changeover applications
- Designed for industrial, commercial and infrastructure power distribution
- Installation, commissioning and maintenance must be completed by a licensed electrical contractor or suitably qualified switchboard professional. Generator changeover installations must be designed, wired and tested in accordance with applicable Australian requirements, including AS/NZS 3000 and AS/NZS 3010.
- Mains-generator automatic changeover
- Commercial and industrial switchboards
- Emergency power systems
- Data centres and critical infrastructure
- Backup power for pumps, HVAC systems and industrial equipment
- Three-phase building and facility power distribution
- Designed to IEC/EN 60947-6-1 for automatic transfer switching equipment
- Relevant Australian/New Zealand transfer-switch standard: AS/NZS 60947.6.1
- Installation should comply with AS/NZS 3000 Wiring Rules
- Generator-connected installations should also be assessed against AS/NZS 3010
- Metal switchgear components can be recovered and recycled at end of service life
- Durable construction and high mechanical endurance can reduce replacement frequency and equipment waste
- Supports reliable use of generator backup systems, helping maintain critical electrical services during mains outages
CHINT warranty policy states that other low-voltage apparatus is generally covered against defects in materials and workmanship for 27 months from the date of manufacture when purchased through authorised sales channels, subject to the applicable sales contract and exclusions.
Available through authorised CHINT distributors in Australia.