ATS 3P 400A High Breaking Type B 400A Frame NXZM Chint
Chint NXZM 400A 3P ATS features CB class changeover, Type B intelligent controller, high breaking capacity and 400A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM 400A ATS, 3P Automatic Changeover Switch, Mains-Generator Transfer Switch, CB Class ATS
- Product Type: Automatic transfer switching equipment
- Model: NXZM-400H/3B 400A
- ATS Class: CB class changeover
- Frame Current: 400A
- Rated Current: 400A
- Number of Poles: 3P
- Rated Operational Voltage: 400/415V AC
- Rated Insulation Voltage: 1000V AC
- Rated Impulse Withstand Voltage: 12kV
- Utilisation Category: AC-33B
- Breaking Capacity: High type, up to 105kA making and 70kA breaking depending on rating configuration
- Controller: Type B intelligent controller
- Control Supply: 230/240V AC, 50Hz
- Control Voltage Range: 85–110% of rated control voltage
- Operating Transfer Time: Approximately 3.5 seconds, ±10%
- Mechanical Endurance: 4,000 operations
- Electrical Endurance: 1,500 operations
- Controller Installation: Built-in
- Protection Degree: IP30, excluding wiring terminals
- Operating Temperature: -5°C to +40°C
- Mounting: Surface or mounting-plate installation
- Communication: RS485 and Modbus RTU available on compatible configurations
- Dimensions (H x L x W): 342mm x 540mm x 234mm
- Weight: 18.78 kg
- Automatic transfer between mains and generator supplies
- CB class changeover using integrated circuit-breaker switching bodies
- Type B intelligent controller for monitoring and automatic control
- High breaking-capacity 400A frame suitable for demanding power-distribution applications
- Supports grid-generator and grid-grid transfer modes
- Adjustable undervoltage, overvoltage, transfer and return-delay functions
- Generator start control and fire-control interface available through the intelligent controller
- Manual, automatic and reset operating modes
- Three-pole configuration for three-phase systems
- Suitable for commercial, industrial and standby-power installations
- Installation, commissioning and connection to mains or generator supplies must be performed by a licensed electrician in accordance with applicable electrical regulations, manufacturer instructions and AS/NZS 3000. Correct neutral switching, fault protection, discrimination and generator interlocking must be verified for the installation.
- Mains-generator automatic changeover systems
- Commercial standby-power installations
- Industrial power-distribution systems
- Data, communications and other critical-load backup supplies
- Building services and infrastructure requiring automatic source transfer
- Three-phase switchboards and generator control panels
- Applicable equipment standard: AS/NZS IEC 60947.6.1:2015 for low-voltage transfer switching equipment; the specific installation must also comply with AS/NZS 3000 and relevant local requirements.
- Supports continued operation of critical electrical systems during mains interruptions, reducing disruption and potential equipment losses
- Durable switchgear construction can extend service life and reduce replacement waste
- Metallic and thermoplastic components can generally be recovered through appropriate electrical-equipment recycling streams at end of life
- Enables controlled generator changeover for efficient use of standby power systems
CHINT warranty policy specifies 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to contract terms and applicable Australian consumer guarantees.
Available through authorised CHINT distributors in Australia.