ATS 3P 400A High Breaking Type B 630A Frame NXZM Chint
Chint NXZM 400A 3P ATS features CB class changeover, Type B intelligent controller, high breaking capacity and 630A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM 630A Frame ATS, 400A 3P Automatic Changeover Switch, Mains-Generator Changeover Switch
- Model: NXZM-630H/3B
- Product Code: 256828
- Rated Current: 400A
- Frame Current: 630A
- Number of Poles: 3P
- Controller: Type B intelligent controller
- Rated Operational Voltage: 400/415V AC
- Frequency: 50Hz
- Utilisation Category: AC-33B
- High-Breaking Version: H type
- Rated Short-Circuit Breaking Capacity: 70kA
- Rated Short-Circuit Making Capacity: 154kA
- Rated Insulation Voltage: 1000V AC
- Rated Impulse Withstand Voltage: 12kV
- Control Supply: 230/240V AC, 50Hz
- Control Voltage Range: 85% to 110% of rated voltage
- Operating Temperature: -25°C to +70°C
- Ingress Protection: IP20
- Mechanical Endurance: 4,000 operations
- Electrical Endurance: 1,500 operations
- Transfer Time: Approximately 3.5 seconds
- Dimensions (H x L x W): 234mm x 540mm x 342mm
- Weight: 18.78 kg
- Three-pole automatic transfer switching for two power sources
- Suitable for mains-generator and normal-emergency supply changeover
- Type B intelligent controller with LCD monitoring and configurable transfer functions
- High-breaking-capacity H version for demanding distribution applications
- 630A frame with a 400A rated operating current
- Integrated mechanical and electrical interlocking
- Manual, automatic and off operating modes
- Padlockable off position for maintenance safety
- Supports remote generator-start and control signalling
- Designed for industrial, commercial and critical-power installations
- Installation, commissioning and testing must be performed by a licensed electrician or suitably qualified electrical contractor. The installation should comply with AS/NZS 3000 and AS/NZS 3010 where a generating set is used, with protection, neutral switching and fault levels verified before energisation.
- Mains-to-generator automatic changeover
- Standby power systems
- Commercial and industrial switchboards
- Data centres and telecommunications facilities
- Hospitals, healthcare buildings and other critical loads
- Manufacturing plants and infrastructure services
- IEC 60947-6-1 product standard; verify the applicable AS/NZS 60947.6.1 adoption and local approval requirements before installation
- AS/NZS 3010:2017 for electrical installations incorporating generating sets
- AS/NZS 3000 for low-voltage electrical installation wiring and protection requirements
- Enables continuity of supply from a standby generator, reducing disruption and potential product or process losses
- Robust moulded-case construction and rated switching endurance can extend service life and reduce replacement waste
- Metal components can be recovered through established electrical equipment recycling streams at end of life
CHINT general warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels. Contract terms and local distributor conditions may vary.