ATS 3P 400A Type A 400A Frame NXZM Chint
Chint NXZM 400A 3P ATS features CB class changeover, Type A standard controller and 400A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM 400A ATS, 3-Pole Automatic Changeover Switch, Mains-Generator Transfer Switch
- Product Type: Automatic transfer switching equipment
- Switching Class: CB class changeover
- Controller: Type A standard controller
- Number of Poles: 3P
- Frame Current: 400 A
- Rated Current: 400 A
- Rated Operational Voltage: 400/415 V AC, 50 Hz
- Utilisation Category: AC-33B
- Rated Insulation Voltage: AC 1000 V
- Rated Impulse Withstand Voltage: 12 kV
- Control Supply Voltage: 230/240 V AC, 50 Hz
- Control Voltage Range: 85% to 110% of rated voltage
- Operating Transfer Time: Approximately 3.3 seconds
- Mechanical Endurance: 4,000 operations
- Electrical Endurance: 1,500 operations
- Installation Configuration: Integrated or split installation
- Enclosure Protection: IP20
- Operating Temperature: -5°C to +40°C
- Dimensions (H x L x W): 535mm x 334mm x 234mm
- Weight: 25 kg
- Automatic transfer between normal mains and standby generator supplies
- Three-pole changeover arrangement for three-phase systems
- CB class switching using moulded-case circuit breaker technology
- Standard Type A controller for essential automatic changeover functions
- 400 A frame and rated current configuration
- Suitable for commercial, industrial and standby-power installations
- Manual operation capability for commissioning and maintenance
- Compatible with 400/415 V, 50 Hz low-voltage distribution systems
- Installation, commissioning and connection to mains or generator supplies must be performed by a licensed electrical contractor in accordance with AS/NZS 3000, AS/NZS 3010 and applicable local requirements. Confirm neutral switching, generator earthing, interlocking and fault-current coordination before installation.
- Mains-generator automatic changeover
- Standby power systems
- Commercial switchboards
- Industrial power distribution
- Emergency and essential services power supplies
- Three-phase backup power installations
- Applicable transfer-switching equipment standard: AS/NZS 60947.6.1
- Generator changeover installations should comply with AS/NZS 3010:2017
- Electrical installation requirements should be assessed against AS/NZS 3000:2018
- CHINT NXZM product family documentation references IEC/EN 60947-6-1; Australian approval and RCM requirements must be confirmed for the specific supplied variant
- Long service life helps reduce replacement frequency and associated equipment waste
- Supports continuity of supply from efficient standby-generation systems
- Metallic switchgear components can generally be recovered through established electrical equipment recycling streams at end of life
CHINT warranty policy states that other low-voltage apparatus is covered against defects in materials and workmanship for 27 months from the date of manufacture when purchased through authorised sales channels. Contract-specific terms may apply.
Available through authorised CHINT distributors in Australia.