ATS 3P 500A High Breaking Type B 630A Frame NXZM Chint
Chint NXZM 500A 3P ATS features CB class changeover, Type B intelligent controller, high breaking capacity and 630A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM-630S/3B 500A ATS, 500A Automatic Changeover Switch, Mains-Generator Transfer Switch, Intelligent Circuit-Breaker ATS
- Model: NXZM-630S/3B 500A
- Rated Current: 500 A
- Frame Current: 630 A
- Number of Poles: 3P
- Switching Type: Circuit-breaker class automatic transfer switch
- Rated Operational Voltage: 400/415 V AC, 50 Hz
- Rated Insulation Voltage: 1,000 V AC
- Utilisation Category: AC-33B
- Short-Circuit Breaking Capacity: 50 kA
- Controller: Type B intelligent controller
- Controller Features: LCD display, monitoring functions and RS-485 communication interface
- Rated Control Supply: 230/240 V AC, 50 Hz
- Operating Transfer Time: Approximately 3.5 seconds, ±10%
- Mechanical Endurance: 4,000 operations
- Electrical Endurance: 1,500 operations
- Operating Temperature: -5°C to +40°C
- Installation: Vertical or horizontal mounting; incoming supply from the top and outgoing supply from the bottom
- Dimensions (H x L x W): 334mm x 234mm x 540mm
- Weight: 18.78 kg
- 500 A rated current with a 630 A frame size
- Three-pole circuit-breaker class automatic transfer design
- 50 kA short-circuit breaking capacity
- Intelligent Type B controller with display and RS-485 communications
- Automatic transfer between normal and alternative supplies
- Suitable for mains-generator and grid-grid changeover applications
- Provides monitoring for supply voltage, phase failure, undervoltage and overvoltage conditions
- Includes adjustable transfer and return delay functions
- Built-in controller and integrated switching assembly
- Manual and automatic operating modes
- Installation, commissioning and connection to mains or generator supplies must be performed by a licensed electrical contractor. The installation must be designed and tested in accordance with AS/NZS 3000 and AS/NZS 3010, with correct source interlocking, neutral and earthing arrangements verified before energisation.
- Mains-generator automatic changeover
- Commercial and industrial standby power systems
- Telecommunications and data centre backup supplies
- Emergency and essential services switchboards
- Factories, warehouses and commercial buildings
- Grid-grid source transfer installations
- High-reliability power distribution systems
- Designed to IEC 60947-1 and IEC 60947-6-1 for low-voltage switchgear and automatic transfer switching equipment
- Australian generator changeover installations should comply with AS/NZS 3010
- Electrical installation and switchboard integration should comply with AS/NZS 3000
- Long mechanical endurance of up to 4,000 operations can reduce replacement frequency and associated equipment waste
- Supports standby power systems that maintain essential loads during mains interruptions
- Durable metal and polymer switchgear components can be separated for responsible recycling at end of service life
CHINT warranty policy generally covers other low-voltage apparatus for 27 months from the date of manufacture when purchased through authorised sales channels. Contractual or regional warranty conditions may vary.
Available through authorised CHINT distributors in Australia.