ATS 3P 500A Type A 630A Frame NXZM Chint
Chint NXZM 500A 3P ATS features CB class changeover, Type A standard controller and 630A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM-630 500A ATS, 3-Phase Automatic Changeover Switch, Mains-Generator Changeover Switch
- Product Type: Class CB automatic transfer switching equipment
- Rated Current: 500 A
- Frame Current: 630 A
- Number of Poles: 3P
- Rated Operational Voltage: 400/415 V AC, 50 Hz
- Utilisation Category: AC-33B
- Controller: Type A standard controller
- Controller Supply: 230/240 V AC, 50 Hz
- Control Voltage Range: 85% to 110% of rated operational voltage
- Rated Insulation Voltage: 1,000 V AC
- Rated Impulse Withstand Voltage: 12 kV
- Rated Short-Circuit Breaking Capacity: 50 kA for S type or 70 kA for H type
- Rated Short-Circuit Making Capacity: 105 kA for S type or 154 kA for H type
- Mechanical Endurance: 4,000 operations
- Electrical Endurance: 1,500 operations
- Operating Transfer Time: Approximately 3.5 seconds
- Installation: Integrated or split controller configuration
- Dimensions (H x L x W): 334mm x 540mm x 234mm
- Weight: 30 kg
- Automatic transfer between normal and alternative power supplies
- Suitable for mains-generator and grid-grid changeover applications
- Circuit-breaker-based Class CB design provides switching and overcurrent protection
- Type A standard controller with LED status indication
- Manual and automatic operating modes
- Under-voltage, over-voltage and phase-failure monitoring
- Adjustable transfer and return delay functions
- Mechanical interlocking helps prevent simultaneous connection of both supplies
- Padlockable off position for maintenance isolation
- Suitable for vertical or horizontal installation
- Installation, commissioning and connection to mains or generator supplies must be performed by a licensed electrical contractor in accordance with the manufacturer's instructions, AS/NZS 3000, AS/NZS 3010 and applicable state or territory electrical regulations. Confirm the required neutral-switching arrangement before installation.
- Automatic mains-generator changeover
- Standby power systems
- Commercial and industrial switchboards
- Data centres and critical power installations
- High-rise building services
- Emergency and backup power distribution systems
- AS/NZS 60947.6.1 for automatic transfer switching equipment
- AS/NZS 3000 for electrical installations and wiring rules
- AS/NZS 3010 for electrical installations incorporating generating sets
- Long mechanical and electrical endurance can reduce replacement frequency and associated waste
- Steel, copper and aluminium components can be recovered for recycling at end of service life
- Automatic power-source management supports continuity of supply and can reduce disruption-related equipment losses
CHINT warranty policy for other low-voltage apparatus provides 27 months from the date of manufacture against defects in materials and workmanship when purchased through authorised sales channels; terms may vary under the supply contract.
Available through authorised CHINT distributors in Australia.