ATS 3P 500A Type B 630A Frame NXZM Chint
Chint NXZM 500A 3P ATS features CB class changeover, Type B intelligent controller and 630A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM-630 500A ATS, 500A 3P Automatic Transfer Switch, Mains-Generator Changeover Switch, Automatic Transfer Switching Equipment
- Product Type: Class CB automatic transfer switching equipment
- Rated Current: 500A
- Frame Size: 630A
- Number of Poles: 3P
- Rated Operational Voltage: 400/415V AC, 50Hz
- Rated Insulation Voltage: 1000V AC
- Utilisation Category: AC-33B
- Control Supply Voltage: 230/240V AC, 50Hz
- Controller Type: Type B intelligent controller
- Controller Functions: Automatic/manual transfer, voltage monitoring, adjustable transfer and return delays, generator start control and RS-485 communication
- Operating Transfer Time: Approximately 3.5 seconds for the 630A frame
- Short-Circuit Capability: 50kA for the standard S breaking-capacity variant; confirm variant before installation
- Installation Mode: Integrated or split controller installation
- Installation Orientation: Vertical or horizontal
- Operating Temperature: -5°C to +40°C standard
- Maximum Installation Altitude: 2000m without derating
- Pollution Degree: 3
- Dimensions (H x L x W): 334mm x 540mm x 234mm
- Weight: 18.78 kg
- CB class automatic transfer switching for mains-to-generator or mains-to-mains applications
- Three-pole configuration with 500A rated current and 630A frame size
- Type B intelligent controller with display, adjustable parameters and system status indication
- Monitors normal and alternative supply voltage conditions
- Supports automatic transfer and automatic or manual restoration modes
- Generator start control and fire-control linkage functions
- RS-485 communication interface with Modbus functionality
- Manual operation and padlockable off-position for maintenance safety
- Suitable for industrial, commercial, building-services and standby-power installations
- Installation, commissioning and connection to mains or generator supplies must be performed by a licensed electrician in accordance with the manufacturer's instructions, AS/NZS 3000 and applicable generator-installation requirements including AS/NZS 3010. Correct phase sequence, neutral arrangements, fault protection and short-circuit coordination must be verified before energisation.
- Mains-generator automatic changeover systems
- Standby power systems for commercial buildings
- Industrial power distribution and control
- Data centres, communications facilities and other critical loads
- High-rise buildings and infrastructure requiring alternate power supply
- Automatic transfer within low-voltage switchboards
- Applicable product standard: AS/NZS IEC 60947.6.1:2015 for transfer switching equipment
- Manufacturer references IEC 60947-1 and IEC 60947-6-1 for the NXZ/NXZM series
- Installation should comply with AS/NZS 3000 and, where connected to generating sets, AS/NZS 3010
- Supports continuity of supply and efficient use of standby generation by automatically transferring loads between power sources
- Durable switchgear construction can extend service life and reduce replacement waste
- Metal switchgear components are generally recyclable at end of service life
- Automatic monitoring and adjustable transfer settings can help limit unnecessary generator operation
CHINT's general policy for other low-voltage apparatus provides a 27-month warranty from the date of manufacture against defects in materials and workmanship when purchased through authorised sales channels, subject to the applicable contract and warranty conditions.