ATS 3P 630A High Breaking Type A 630A Frame NXZM Chint
Chint NXZM 630A 3P ATS features CB class changeover, Type A standard controller, high breaking capacity and 630A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: NXZM 630A ATS, 630A automatic changeover switch, mains-generator transfer switch, CB-class automatic transfer switching equipment
- Product Type: Class CB automatic transfer switching equipment
- Frame Current: 630A
- Rated Current: 630A
- Number of Poles: 3P
- Rated Operational Voltage: 400/415V AC
- Frequency: 50Hz
- Utilisation Category: AC-33B
- Rated Short-Circuit Breaking Capacity: 70kA
- Rated Short-Circuit Making Capacity: 154kA
- Rated Insulation Voltage: 1,000V
- Rated Impulse Withstand Voltage: 12kV
- Controller: Type A standard controller
- Control Supply Voltage: 230/240V AC
- Operating Transfer Time: Approximately 3.5 seconds
- Mechanical Endurance: 4,000 operations
- Electrical Endurance: 1,500 operations
- Installation: Integrated or split controller installation options
- Dimensions (H x L x W): 464mm x 234mm x 540mm
- Weight: 24 kg
- High-breaking-capacity H version for demanding low-voltage applications
- 630A frame and 630A rated current
- Three-pole mains-generator changeover configuration
- CB-class transfer equipment with mechanically interlocked switching
- Type A standard controller for automatic and manual operation
- Automatic transfer between normal and standby power sources
- Suitable for generator-start control applications
- Designed for industrial, commercial and critical power installations
- Installation, commissioning and connection must be performed by a licensed electrician or suitably qualified electrical contractor. The installation should be designed and verified in accordance with AS/NZS 3000, AS/NZS 3010 and the requirements for the completed switchboard assembly under the AS/NZS 61439 series.
- Mains-to-generator automatic changeover
- Standby power systems
- Commercial and industrial switchboards
- Data centres and critical power installations
- High-load building services
- Manufacturing and infrastructure power distribution
- Applicable installation requirements under AS/NZS 3000
- Generator and automatic changeover installation requirements under AS/NZS 3010:2017
- Completed low-voltage switchboard assembly requirements under the AS/NZS 61439 series
- Product design is specified to IEC 60947-1 and IEC 60947-6-1; verify Australian approval and local certification requirements before installation
- Durable low-voltage switchgear construction can reduce replacement frequency and associated waste
- Metal components can be recovered and recycled at end of service life
- Automatic generator changeover supports continuity of supply and can help avoid losses caused by power interruptions
CHINT's general policy for other low-voltage apparatus provides 27 months against defects in materials and workmanship from the date of manufacture when supplied through authorised sales channels; contract-specific terms may apply.
Available through authorised CHINT distributors in Australia.