ATS 3P 630A Type A 630A Frame NXZM Chint
Chint NXZM 630A 3P ATS features CB class changeover, Type A standard controller and 630A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM-630S/3A ATS, 630A Automatic Changeover Switch, 3-Phase Mains-Generator Transfer Switch, Class CB ATS
- Product Series: NXZM
- Configuration: 3-pole, Class CB automatic transfer switching equipment
- Frame Current: 630A
- Rated Current: 630A
- Rated Operational Voltage: 400/415V AC
- Frequency: 50Hz
- Rated Insulation Voltage: AC1000V
- Rated Impulse Withstand Voltage: 12kV
- Utilisation Category: AC-33B
- Controller: Type A standard controller with LED indication
- Control Supply Voltage: 230/240V AC, 50/60Hz
- Control Voltage Range: 85% to 110% of rated operational voltage
- Operating Transfer Time: Approximately 3.5 seconds
- Installation Mode: Integrated or split controller installation
- Product Standards: IEC 60947-1 and IEC 60947-6-1
- Environmental Ratings: IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-30 and IEC 60068-2-11
- Maximum Recommended Altitude: 2000m above sea level
- Operating Temperature: 5°C to 40°C standard; extended -25°C to 70°C application available with temperature compensation
- Dimensions (H x L x W): 272mm x 430mm x 230mm
- Weight: 35 kg
- Automatic transfer between normal and alternative power supplies
- Suitable for mains-generator changeover applications
- Class CB design capable of switching normal load and short-circuit currents within its specified ratings
- Type A standard controller with LED status indication
- Manual and automatic operating modes
- Normal, alternative and off-position switching
- Monitors phase loss, undervoltage and overvoltage conditions
- Adjustable transfer, return and generator start delays from 0 to 300 seconds
- Generator start control output
- Mechanical interlock and padlockable off position for maintenance safety
- Suitable for industrial, commercial, high-rise and residential power installations
- Installation, commissioning and maintenance must be performed by a licensed electrical contractor or suitably qualified electrician. Generator and switchboard connections must be designed and installed in accordance with AS/NZS 3000 and AS/NZS 3010, with correct phase sequence, neutral configuration, upstream short-circuit protection and manual isolation provisions.
- Mains-to-generator automatic changeover
- Standby power systems
- Commercial and industrial switchboards
- Data centres and telecommunications facilities
- High-rise building essential services
- Residential or light-commercial backup power systems
- Critical load and emergency power distribution
- AS/NZS 3000 for electrical installations
- AS/NZS 3010:2017 for generator-connected electrical installations and automatic changeover arrangements
- AS/NZS 61439 series for the switchboard or low-voltage assembly in which the ATS is installed
- Supports continued operation of essential electrical loads during mains interruptions, reducing downtime and potential equipment losses
- Robust switchgear construction is intended for repeated transfer operations and extended service life, reducing replacement waste
- Metal switchgear components can generally be recovered through established electrical equipment recycling streams at end of life
CHINT warranty policy states that other low-voltage apparatus is covered against defects in materials and workmanship for 27 months from the date of manufacture when purchased through authorised sales channels. The applicable warranty may be varied by the sales contract.
Available through authorised CHINT distributors in Australia.