ATS 3P 630A Type A 800A Frame NXZM Chint
Chint NXZM 630A 3P ATS features CB class changeover, Type A standard controller and 800A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM-800S/3A 630A ATS, 3-Phase Automatic Changeover Switch, Mains-Generator Transfer Switch, Class CB ATS
- Product Type: Automatic transfer switching equipment
- Switching Class: Class CB circuit-breaker changeover
- Number of Poles: 3P
- Rated Current: 630 A
- Frame Current: 800 A
- Controller: Type A standard controller
- Rated Working Voltage: 400/415 V AC
- Rated Frequency: 50/60 Hz
- Utilisation Category: AC-33B
- Rated Insulation Voltage: 1000 V AC
- Rated Impulse Withstand Voltage: 12 kV
- Rated Short-Circuit Making Capacity Icm: Up to 105 kA, dependent on breaking type
- Rated Short-Circuit Breaking Current Icn: Up to 50 kA, dependent on breaking type
- Mechanical Durability: Up to 4500 operations
- Electrical Durability: Up to 1500 operations
- Connection Arrangement: Top incoming, bottom outgoing; incoming connections on the same side
- Transfer Function: Automatic transfer between normal and alternative power supplies
- Dimensions (H x L x W): 464mm x 535mm x 342mm
- Weight: 35 kg
- 3-pole automatic changeover for three-phase power systems
- 630A operating rating with an 800A frame size
- Class CB construction using mechanically interlocked circuit breakers
- Type A controller for automatic and manual switching operation
- Suitable for mains-generator changeover applications
- Voltage-loss, undervoltage and overvoltage monitoring on the normal supply
- Three-position switching arrangement with normal supply, alternative supply and off positions
- Designed for industrial, commercial and building emergency power systems
- Installation, testing and commissioning must be performed by a licensed electrical contractor. Generator changeover wiring, isolation, neutral-earth arrangements and interlocking must comply with AS/NZS 3000 and AS/NZS 3010, together with the manufacturer's instructions.
- Mains-to-generator automatic changeover
- Commercial and industrial emergency power systems
- High-rise and residential building backup power
- Critical load supply changeover
- Generator switchboards and distribution boards
- Automatic transfer between two independent three-phase power supplies
- Product design is based on IEC 60947-1 and IEC 60947-6-1 requirements for low-voltage automatic transfer switching equipment
- Generator changeover installations should be designed and installed in accordance with AS/NZS 3010:2017
- Electrical installation requirements should be assessed against AS/NZS 3000:2018
- Supports reuse of existing electrical infrastructure by automatically transferring critical loads to backup generation
- Robust circuit-breaker construction and high operating endurance can reduce replacement waste over the service life
- Steel, copper and aluminium components are recyclable at end of life
- Automatic backup operation can help maintain essential equipment and services during supply interruptions
CHINT warranty policy generally provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to the applicable sales contract and warranty conditions.
Available through authorised CHINT distributors in Australia.