ATS 3P 630A Type B 800A Frame NXZM Chint
Chint NXZM 630A 3P ATS features CB class changeover, Type B intelligent controller and 800A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM 800A Frame ATS, 630A Mains-Generator Changeover Switch, CB-Class Automatic Transfer Switching Equipment
- Rated Current: 630 A
- Frame Current: 800 A
- Number of Poles: 3P
- Rated Operational Voltage: 400/415 V AC, 50 Hz
- Rated Insulation Voltage: 1,000 V AC
- Utilisation Category: AC-33B
- Short-Circuit Breaking Capacity: 50 kA at 400 V AC, S version
- Controller: Type B intelligent controller
- Control Supply Voltage: 230/240 V AC, 50 Hz
- Transfer Operating Time: Approximately 4 seconds
- Installation Mode: Integrated or split installation
- Protection Rating: IP30, excluding wiring terminals
- Mechanical Endurance: 4,000 operations
- Electrical Endurance: 1,000 operations
- Product Standard: IEC/EN 60947-6-1
- Dimensions (H x L x W): 344mm x 660mm x 228mm
- Weight: 40 kg
- CB-class automatic transfer switch based on moulded-case circuit breakers
- 630 A switching capacity within an 800 A frame size
- Three-pole configuration for three-phase mains-generator changeover
- Intelligent Type B controller for automatic source monitoring and transfer
- Supports automatic and manual operating modes
- Provides overload and short-circuit protection through integrated circuit breakers
- Suitable for mains-mains or mains-generator transfer applications
- Control functions can include generator start signalling and adjustable transfer parameters
- RS485 communication capability available within the NXZM range
- Installation, commissioning and connection to mains or generator supplies must be completed by a licensed electrician in accordance with applicable electrical regulations, AS/NZS 3000 and AS/NZS 3010. The switch must be correctly coordinated with upstream protection and the generator earthing and neutral arrangement.
- Mains-generator automatic changeover systems
- Standby power systems for commercial and industrial buildings
- Emergency power distribution
- Data centres, telecommunications facilities and critical infrastructure
- Industrial switchboards and motor supply systems
- Automatic transfer between two three-phase AC sources
- IEC/EN 60947-6-1 automatic transfer switching equipment requirements
- AS/NZS 3947.6.1 for automatic transfer switching equipment where applicable
- AS/NZS 3000 electrical installation requirements
- AS/NZS 3010 generating-set installation requirements for mains-generator systems
- Durable moulded-case construction can extend service life and reduce replacement waste
- Copper, aluminium and steel components can be recovered through established electrical equipment recycling streams
- Automatic source transfer helps maintain continuity of supply and can reduce losses associated with unplanned shutdowns
CHINT low-voltage apparatus supplied through authorised sales channels is covered for defects in materials and workmanship for 27 months from the date of manufacture, subject to the applicable sales contract and warranty conditions.
Available through authorised CHINT distributors in Australia.