ATS 3P 63A High Breaking Type A 125A Frame NXZM Chint
Chint NXZM 63A 3P ATS features CB class changeover, Type A standard controller, high breaking capacity and 125A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM ATS, Automatic Transfer Switching Equipment, Mains-Generator Changeover Switch, CB Class ATS
- Model: NXZM-125H/3A 63A
- Equipment Type: Automatic transfer switching equipment
- Switching Class: CB class
- Number of Poles: 3P
- Rated Current: 63 A
- Frame Current: 125 A
- Rated Operational Voltage: 400/415 V AC, 50 Hz
- Rated Insulation Voltage: 800 V AC
- Rated Impulse Withstand Voltage: 8 kV
- Rated Short-Circuit Breaking Capacity: 50 kA
- Rated Short-Circuit Making Capacity: 105 kA
- Utilisation Category: AC-33B
- Controller: Type A standard controller
- Control Supply: 230/240 V AC, 50 Hz
- Control Voltage Range: 85% to 110% of rated voltage
- Typical Operating Transfer Time: 2.8 seconds
- Installation: Integrated or split installation
- Ingress Protection: IP30, excluding wiring terminals
- Dimensions (H x L x W): 190mm x 312mm x 223mm
- Weight: 0.9 kg
- Automatic changeover between normal and alternative power supplies
- Suitable for mains-generator changeover applications
- High-breaking H type with 50 kA breaking capacity
- CB class switching arrangement with integrated circuit-breaker protection
- Type A standard controller for automatic operation
- Manual and automatic operating modes
- Supports vertical or horizontal installation
- 3-pole configuration for three-phase systems
- Installation, commissioning and maintenance must be performed by a licensed electrician or suitably qualified electrical professional. The unit must be integrated into the mains and generator system in accordance with AS/NZS 3000, AS/NZS 3010, manufacturer instructions and applicable local electrical regulations.
- Mains-generator automatic changeover
- Standby power systems
- Commercial and industrial switchboards
- Three-phase emergency power installations
- Critical-load power continuity systems
- AS/NZS IEC 60947.6.1:2015 for low-voltage transfer switching equipment
- AS/NZS 3000 for electrical installation work
- AS/NZS 3010:2017 for electrical installations incorporating generating sets
- Durable moulded-case construction can support extended service life and reduce replacement waste
- Copper and metal components are recyclable at end of service life
- Automatic transfer operation supports continued use of standby generation systems and reduces interruption-related equipment losses
CHINT warranty policy specifies 27 months from the date of manufacture for other low-voltage apparatus sold through authorised sales channels, subject to the applicable customer contract and warranty conditions.
Available through authorised CHINT distributors in Australia.