ATS 3P 800A High Breaking Type A 800A Frame NXZM Chint
Chint NXZM 800A 3P ATS features CB class changeover, Type A standard controller, high breaking capacity and 800A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM-800 ATS, 800A Automatic Changeover Switch, 3-Phase Mains-Generator Transfer Switch, Class CB ATS
- Rated Current: 800 A
- Frame Current: 800 A
- Number of Poles: 3P
- Equipment Class: Class CB automatic transfer switching equipment
- Controller: Type A basic controller
- Rated Working Voltage: AC 400/415 V
- Rated Frequency: 50/60 Hz
- Rated Insulation Voltage: 1,000 V
- Rated Impulse Withstand Voltage: 12 kV
- Utilisation Category: AC-33B
- High Breaking Capacity: 70 kA rated short-circuit breaking current
- Rated Short-Circuit Making Capacity: 154 kA
- Mechanical Durability: 4,500 operations
- Electrical Durability: 1,000 operations
- Contact Action Time: Up to 2 seconds
- Conversion Action Time: Up to 3 seconds
- Switch Positions: Power supply I, power supply II and power off
- Connection: Top in, bottom out; incoming connections on the same side
- Dimensions (H x L x W): 477mm x 660mm x 385mm
- Weight: 55 kg
- Automatic transfer between two three-phase power supplies
- Suitable for mains-generator changeover applications
- Class CB configuration incorporates circuit-breaker-based switching and protection
- High breaking version for installations with higher prospective fault current
- Type A controller provides automatic and manual switching control
- Voltage-loss, phase-loss, undervoltage and overvoltage monitoring on the primary supply
- Automatic transfer and automatic recovery operation
- Visual indication of power supply and switch status
- Manual, automatic and power-off operating positions
- Compatible with industrial, commercial and building electrical distribution systems
- Installation, commissioning and servicing must be performed by a licensed electrical contractor. The equipment must be selected, wired and tested in accordance with AS/NZS 3000, applicable generator-installation requirements and the manufacturer's instructions. Particular care is required for three-phase neutral arrangements, source interlocking and prevention of generator backfeed.
- Mains-to-generator automatic changeover
- Standby power systems
- Commercial and industrial switchboards
- Data centres and telecommunications facilities
- High-rise and residential building services
- Emergency and critical-load distribution systems
- Three-phase dual-source power distribution
- AS/NZS 60947.6.1: Automatic transfer switching equipment
- AS/NZS 3000: Electrical installations and wiring rules
- AS/NZS 3010: Electrical installations incorporating generating sets
- Long service life can reduce replacement frequency and associated electrical equipment waste
- Supports efficient use of standby generation by transferring loads only when the primary supply is abnormal
- Durable switchgear construction helps extend the service life of electrical distribution systems
CHINT low-voltage apparatus is generally covered for 27 months from the date of manufacture when purchased through authorised sales channels, subject to the applicable supply contract and warranty conditions.
Available through authorised CHINT distributors in Australia.