ATS 4P 200A High Breaking Type A 250A Frame NXZM Chint
Chint NXZM 200A 4P ATS features CB class changeover, Type A standard controller, high breaking capacity and 250A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM 200A ATS, Automatic Changeover Switch, Mains-Generator Transfer Switch, CB Class Transfer Switching Equipment
- Product Type: Class CB automatic transfer switching equipment
- Rated Current: 200 A
- Frame Current: 250 A
- Number of Poles: 4P, 3P plus neutral
- Breaking Capacity: High breaking type, 50 kA at 400/415 V AC
- Utilisation Category: AC-33B
- Rated Operational Voltage: 400/415 V AC
- Rated Insulation Voltage: 800 V
- Rated Impulse Withstand Voltage: 8 kV
- Rated Frequency: 50/60 Hz
- Controller: Type A standard controller
- Control Circuit Voltage: 230/240 V AC
- Contact Transfer Time: Approximately 2 x 1 second
- Operating Transfer Time: Approximately 3.3 seconds
- Mechanical Endurance: 6,000 operating cycles
- Electrical Endurance: 2,000 operating cycles
- Pollution Degree: 3
- Installation Category: III for the main circuit
- Enclosure Protection: IP20
- Mounting: Mounting plate installation
- Connection: Cable or copper busbar connection
- Dimensions (H x L x W): 216mm x 390mm x 250mm
- Weight: 12 kg
- Automatic transfer between normal and alternative power supplies
- Suitable for mains-generator changeover applications
- CB class construction using moulded-case circuit breakers
- High 50 kA short-circuit breaking capacity
- Four-pole switching for three-phase systems with neutral switching
- Standard Type A controller for automatic voltage monitoring and transfer control
- Adjustable transfer and return delay functions
- Manual and automatic operating modes
- Integrated protection against overload and short circuit
- Front-mounted operating and status indications
- Installation, commissioning and maintenance must be carried out by a licensed electrician or suitably qualified electrical professional. Install and connect the equipment in accordance with the manufacturer's instructions, AS/NZS 3000 and, where used with generating sets, AS/NZS 3010. Confirm system voltage, neutral switching arrangement, fault level, cable or busbar sizing and protection coordination before energising.
- Mains-generator automatic changeover
- Commercial and industrial standby power systems
- Emergency power distribution
- Three-phase switchboards with switched neutral requirements
- Critical loads requiring automatic transfer between two AC power sources
- AS/NZS IEC 60947.6.1:2015 for low-voltage transfer switching equipment
- AS/NZS 3000 for electrical installations and wiring
- AS/NZS 3010:2017 for electrical installations incorporating generating sets
- Supports continuity of power to critical equipment, reducing disruption and potential product or process waste during mains outages
- Long service life and high operating endurance can reduce replacement frequency and associated material waste
- Moulded-case electrical equipment contains recyclable metal conductors and structural components at end of service life
CHINT warranty policy generally provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to the applicable sales contract and warranty conditions.