ATS 4P 400A Type A 630A Frame NXZM Chint
Chint NXZM 400A 4P ATS features CB class changeover, Type A standard controller and 630A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM-630S/4A 400A ATS, 4P Automatic Changeover Switch, Mains-Generator Transfer Switch, CB-Class ATS
- Product Type: Automatic transfer switching equipment
- Switching Class: CB class with circuit-breaker protection
- Rated Current: 400 A
- Frame Current: 630 A
- Number of Poles: 4P
- Rated Operational Voltage: 400/415 V AC
- Rated Frequency: 50/60 Hz
- Utilisation Category: AC-33B
- Rated Insulation Voltage: 1000 V AC
- Rated Impulse Withstand Voltage: 12 kV
- Rated Short-Circuit Making Capacity: 105 kA
- Rated Short-Circuit Breaking Capacity: 50 kA
- Controller: Type A standard controller
- Rated Control Supply: 230/240 V AC
- Control Voltage Range: 85% to 110% of rated voltage
- Typical Operating Transfer Time: 3.5 seconds
- Mechanical Endurance: 4000 operations
- Electrical Endurance: 1500 operations
- Enclosure Protection: IP20
- Normal Operating Temperature: -5°C to +40°C
- Installation Category: III
- Pollution Degree: 3
- Dimensions (H x L x W): 535mm x 304mm x 475mm
- Weight: 35 kg
- Automatic transfer between normal mains and generator supplies
- Four-pole switching suitable for three-phase four-wire systems
- 630A frame with 400A rated operational current
- CB-class construction using mechanically interlocked circuit breakers
- Type A standard controller for automatic monitoring and changeover
- Adjustable voltage monitoring and transfer delay functions
- Manual and automatic operating modes
- Integrated controller installation arrangement
- Suitable for industrial, commercial and building power systems
- Installation, commissioning and maintenance must be performed by a licensed electrical contractor. The installation should comply with AS/NZS 3000 and, where connected to a generating set, AS/NZS 3010. Verify supply configuration, neutral switching requirements, fault level, discrimination and local certification requirements before energisation.
- Mains-generator automatic changeover systems
- Standby power installations
- Commercial and industrial switchboards
- High-rise and residential building backup supplies
- Critical-load and emergency power distribution systems
- AS/NZS IEC 60947.6.1:2015 for transfer switching equipment
- AS/NZS 3010:2017 for electrical installations incorporating generating sets
- AS/NZS 3000 for electrical installation and switchboard wiring requirements
- Supports continuity of supply and reduces interruption-related equipment downtime
- Durable switchgear construction can extend service life and reduce replacement waste
- Metal and electrical components can be separated for responsible recycling at end of service life
CHINT's general policy for other low-voltage apparatus provides 27 months from the date of manufacture against defects in materials and workmanship when purchased through authorised sales channels. Contract-specific terms may apply.
Available through authorised CHINT distributors in Australia.