ATS 4P 80A High Breaking Type B 125A Frame NXZM Chint
Chint NXZM 80A 4P ATS features CB class changeover, Type B intelligent controller, high breaking capacity and 125A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM High-Breaking ATS, 4-Pole Automatic Changeover Switch, Mains-Generator Transfer Switch, Automatic Transfer Switching Equipment
- Equipment Type: Automatic transfer switching equipment with circuit-breaker switching
- Rated Current: 80 A
- Frame Current: 125 A
- Number of Poles: 4P
- Rated Operational Voltage: 400/415 V AC, 50 Hz
- Rated Insulation Voltage: 800 V AC
- Rated Impulse Withstand Voltage: 8 kV
- Utilisation Category: AC-33B
- Rated Short-Circuit Making Capacity: 105 kA for H type
- Rated Short-Circuit Breaking Capacity: 50 kA for H type
- Controller: Type B intelligent controller
- Control Supply: 230/240 V AC, 50 Hz
- Control Voltage Range: 85% to 110% of rated voltage
- Operating Transfer Time: Approximately 2.8 seconds ±10%
- Mechanical Endurance: 10,000 operations
- Electrical Endurance: 2,000 operations
- Installation Configuration: Built-in controller, surface mounting
- Transfer Functions: Automatic transfer and restoration, adjustable delays, undervoltage, overvoltage and phase-loss transfer
- Generator Interface: Generator start control and mains-generator changeover
- Dimensions (H x L x W): 240mm x 190mm x 300mm
- Weight: 5 kg
- High-breaking H-class construction with 50 kA rated short-circuit breaking capacity
- Four-pole switching for three-phase systems with neutral changeover
- 125 A frame with an 80 A rated operating current
- Type B intelligent controller with voltage monitoring and adjustable transfer settings
- Supports mains-generator and mains-mains changeover applications
- Automatic transfer, automatic restoration and manual operating modes
- Built-in generator start control and fire-control interface functions
- Moulded-case circuit-breaker construction with integrated overcurrent protection
- Installation, commissioning and testing must be performed by a licensed electrician in accordance with the manufacturer's instructions, AS/NZS 3000 and applicable generator-installation requirements including AS/NZS 3010. Correct neutral switching, earthing, interlocking, fault-current coordination and generator control wiring must be verified before energisation.
- Mains-to-generator automatic changeover
- Standby power systems
- Commercial and industrial distribution boards
- Three-phase emergency power systems
- Critical-load and essential-services power supplies
- Mains-to-mains source transfer installations
- AS/NZS 3947.6.1:2001 for low-voltage automatic transfer switching equipment
- AS/NZS 3000 for electrical installation and wiring requirements
- AS/NZS 3010 for electrical installations incorporating generating sets
- IEC 60947-1 and IEC 60947-6-1 design reference standards
- Enables continued operation of essential electrical loads during mains interruptions, reducing downtime and potential product or process waste
- Durable moulded-case construction and rated mechanical endurance support long service life and reduce replacement frequency
- Automatic source selection can support efficient use of standby generation by transferring only when required
CHINT’s general policy for other low-voltage apparatus provides a 27-month warranty from the date of manufacture when purchased through authorised sales channels, subject to the applicable sales contract and local distributor terms.
Available through authorised CHINT distributors in Australia.