ATS 4P 80A Type B 125A Frame NXZM Chint
Chint NXZM 80A 4P ATS features CB class changeover, Type B intelligent controller and 125A frame. Ideal for mains-generator changeover.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NXZM-125S/4B 80A ATS, 4P Automatic Changeover Switch, Mains-Generator Transfer Switch, Automatic Transfer Switching Equipment
- Product Type: Class CB automatic transfer switching equipment
- Rated Current: 80 A
- Frame Current: 125 A
- Number of Poles: 4P
- Controller: Type B intelligent controller
- Rated Operational Voltage: 400/415 V AC, 50 Hz
- Rated Insulation Voltage: 800 V AC
- Rated Impulse Withstand Voltage: 8 kV
- Utilisation Category: AC-33B
- Rated Control Supply: 230/240 V AC, 50 Hz
- Control Voltage Range: 85% to 110% of rated control voltage
- Short-Circuit Rating: 25 kA for the S version or 50 kA for the H version
- Transfer Operation Time: Approximately 2.8 seconds, subject to the selected series and operating conditions
- Installation Method: Surface mounting, vertical or horizontal installation
- Switching Modes: Automatic, manual and reset operation
- Generator Function: Generator start control and mains-generator operating mode
- Dimensions (H x L x W): 240mm x 300mm x 178mm
- Weight: 1.5 kg
- Automatic changeover between normal mains and alternative generator supply
- Four-pole switching suitable for three-phase systems with neutral switching
- Intelligent Type B controller for supply monitoring and automatic transfer management
- 125A moulded-case frame with an 80A rated current configuration
- Adjustable transfer and return delay functions
- Supports automatic transfer, automatic restoration and manual operation
- Provides undervoltage, phase-loss and supply-failure transfer functions
- Manual operating handle and lockable off position for maintenance isolation
- Suitable for grid-generator and grid-grid changeover applications
- Installation, configuration and commissioning must be performed by a licensed electrical contractor in accordance with the manufacturer's instructions, AS/NZS 3000 and AS/NZS 3010. Verify the exact short-circuit rating and supply arrangement before installation.
- Mains-generator automatic changeover systems
- Standby power systems for commercial buildings
- Industrial power distribution and control panels
- Data, communications and other critical-load backup systems
- Three-phase installations requiring switched neutral changeover
- Designed to IEC 60947-6-1 for transfer switching equipment
- AS/NZS IEC 60947.6.1:2015 is the applicable Australian/New Zealand transfer switching equipment standard to verify for the installation
- AS/NZS 3010:2017 applies to electrical installations incorporating generating sets
- AS/NZS 3000 applies to the associated electrical installation and wiring
- Durable moulded-case construction supports extended service life and can reduce replacement waste
- Automatic transfer helps maintain continuity of supply for critical systems, reducing disruption and potential equipment losses
- Suitable for integration into efficient standby-power systems that avoid unnecessary generator operation through automatic supply monitoring
CHINT's general warranty policy states that other low-voltage apparatus is covered against defects in materials and workmanship for 27 months from the date of manufacture when purchased through authorised sales channels; contract terms may vary.
Available through authorised CHINT distributors in Australia.