SCHNAP Logo

Making Trade Life Easy!
Trade Discount 25%

CT Chamber 400A 650x400x250mm Type S Tray Orange Bovara

SKU: CTC400M
$3,178.00 List price: $4,237.30
+
Bovara 400A CT chamber features 650H x 400W x 250D 2mm mild steel body, IP20, split gland plates and Type S CT tray, X15 orange gloss. CTs not included.

Alternatively Known As: CT Chamber, Current Transformer Chamber, CT Metering Enclosure, Type S CT Enclosure

Technical Specifications
  • Product Code: CTC400M
  • Chamber Designation: 400A
  • CT Application: 200/5A current transformers
  • CT Type: Type S
  • Enclosure Material: 2mm mild steel
  • Ingress Protection: IP20
  • Finish: Orange X15 gloss powder coating
  • Cable Entry: Two 50mm diameter knockouts on each side, with top and bottom entry
  • Gland Plates: Split gland plates supplied and fitted
  • Cover: Lift-off cover with provision for sealing
  • Earth Connection: Earth stud included
  • Busbar Accommodation: One 300mm² or two 185mm² conductors suitable for one phase
  • Included Items: Type S CT tray and enclosure; current transformers not included
  • Dimensions (H x L x W): 650mm x 250mm x 400mm
  • Weight: 22 kg
Key Features
  • Designed for Type S current transformer metering applications
  • Robust 2mm mild steel construction
  • Orange X15 gloss powder-coated finish
  • Split gland plates simplify cable installation
  • Top, bottom and side cable entry provisions
  • Lift-off cover with sealing provision
  • Earth stud included
  • Current transformers are not included
Professional Installation Requirements
  • Installation, cable termination and connection to an energised electrical installation must be performed by a licensed electrician or suitably qualified electrical contractor in accordance with AS/NZS 3000, applicable network-operator requirements and the required metering configuration. Confirm CT compatibility before installation.
Applications
  • Commercial current transformer metering installations
  • Main switchboards and distribution switchboards
  • Electrical energy monitoring systems
  • Indoor power-distribution and metering applications
Standards & Compliance
  • AS/NZS 61439 for low-voltage switchgear and controlgear assemblies
Environmental Benefits
  • Mild steel enclosure components are recyclable at end of service life
  • Durable powder-coated construction can extend service life and reduce replacement waste
  • Current transformer metering supports electrical monitoring and energy-management applications
Warranty Information

No specific Bovara warranty period is published for this product. Warranty is subject to the applicable supplier and manufacturer terms.

Available Now

Available through authorised Bovara distributors in Australia.