D8XD Alarm Kit with KPX+ Keypad and Guardall GP15 PIR Ness
Ness D8XD alarm kit features a KPX+ keypad and Guardall GP15 PIR detector. Ideal for home and business alarm systems.
Sign in
Please login to continue to your account.
Alternatively Known As: Ness D8XD Security Alarm Kit, Ness D8X Deluxe Alarm Panel Kit, Guardall GP15 PIR Alarm Kit
- Control Panel: Ness D8XD 8-zone deluxe alarm panel
- Keypad: Ness KPX+ white LCD keypad, part number 106-310
- Motion Detectors: 2 x Guardall GP15 15 m PIR detectors, part number 122-001
- Backup Battery: 12 V 7 Ah sealed lead-acid battery
- Panel Power Supply: 15 V DC, 2 A via converter, or 17 VAC/20 V DC depending on panel variant
- Panel Inputs: 8 programmable zones with monitored end-of-line resistors
- Keypad Voltage: 12 V DC supplied by the control panel
- PIR Detection Range: 15 m at 90 degrees; 10 m at 90 degrees with pet mode
- PIR Operating Voltage: 9–15 V DC
- PIR Maximum Current: 12 mA at 12 V
- PIR Operating Temperature: -10 °C to 55 °C
- PIR Environmental Rating: 0–95% relative humidity, non-condensing
- PIR Security Classification: EN 50131-2-2, Grade 2 Class II
- Telephone Reporting: Traditional PSTN reporting is no longer suitable following the Australian NBN landline decommissioning; local alarm operation remains supported
- Dimensions (H x L x W): 300mm x 90mm x 235mm
- Weight: 3.5 kg
- Complete D8XD alarm panel, keypad and PIR detector kit
- Eight-zone hardwired alarm control panel for residential and commercial applications
- High-contrast KPX+ LCD keypad with white backlighting and red alarm-memory backlighting
- Two Guardall GP15 passive infrared detectors with 15 m coverage
- 12 V 7 Ah sealed lead-acid backup battery included
- Supports local audible alarm operation and optional access-control accessories
- Ness D8XD panel manufactured in Australia; Guardall GP15 detectors manufactured in the UK
- Suitable for use with current alarm reporting upgrades where compatible 4G or IP equipment is added
- Installation, mains connection, alarm-zone wiring, programming and commissioning should be completed by a suitably qualified security alarm installer. Installation should follow applicable requirements of AS/NZS 2201.1 and relevant electrical regulations. The included PSTN dialler should not be relied on for modern back-to-base monitoring without a compatible communications upgrade.
- Residential intruder alarm systems
- Small commercial security systems
- Office, retail and light-industrial premises
- Local alarm systems requiring hardwired PIR detection
- Replacement or upgrade installations using compatible Ness D8X/D16X equipment
- AS/NZS 2201.1:2007 — applicable to the design, installation, commissioning and maintenance of intruder alarm systems at client premises; system compliance depends on the complete installation
- AS/NZS CISPR 22:2002 Class B — EMC requirement listed in the D8XD installation manual; verify applicability for the installed product revision
- Supplied sealed lead-acid backup battery can be recovered through approved battery-recycling channels
- Ness provides RoHS compliance documentation for its product range, supporting restriction of hazardous substances in electronic components
- Long-service hardwired control-panel and detector architecture can reduce replacement frequency compared with disposable wireless components
- Electronic alarm equipment should be separated from general waste and processed through appropriate e-waste recycling channels at end of life
Ness manufactured or supplied products are covered by a 3-year warranty from the date of purchase unless otherwise specified. Warranty exclusions and claim conditions apply. ([ness.com.au](https://ness.com.au/product-warranty?utm_source=openai))
Available through Ness and authorised Australian security distributors; confirm current stock, product revision and compatibility with modern 4G or IP alarm reporting equipment before purchase. ([ness.com.au](https://ness.com.au/k-6410))