'Dura G2 Weatherproof Emergency Batten 655mm 10/13/15/18W Haneco'
'Haneco Dura G2 weatherproof emergency batten features 655mm length, 10/13/15/18W power and 4000/4500/5000K CCT. Ideal for emergency lit carparks.'
Sign in
Please login to continue to your account.
Alternatively Known As: Haneco DURA06-EM-G2, Emergency Weatherproof LED Batten, Emergency Triproof Batten, LED Emergency Batten
- Product Code: DURA06-EM-G2
- Rated Power: 10 / 13 / 15 / 18 W
- Colour Temperature: 4000 / 4500 / 5000 K selectable
- Emergency Discharge Time: 3 hours
- Battery Type: LiFePO4 3.2 V, 3.2 Ah
- Battery Recharge Time: 24 hours
- Emergency Charging Power: 3 W
- Emergency Standby Power: Less than 1 W
- Emergency Operation: Maintained and non-maintained
- Emergency Test Type: Manual test
- Emergency Classification: C0:D40, C90:D25
- Input Voltage: 220–240 Vac, 50/60 Hz
- Power Factor: Greater than 0.9
- Beam Angle: 120°
- Ingress Protection: IP65
- Impact Protection: IK08
- Insulation Class: Class I
- Body Material: Polycarbonate
- Diffuser Material: Opal polycarbonate
- Mounting: Surface mount or suspended
- Operating Temperature: 0°C to 40°C for emergency operation
- Flicker-Free: Yes
- Projected Lifespan: Greater than 102,000 hours at 40°C, L70
- Fascia Colour: Grey
- Driver: Integral
- Dimensions (H x L x W): 75mm x 655mm x 102mm
- Weight: 0.99 kg
- Emergency weatherproof batten for car parks, warehouses, workshops and public facilities
- Selectable 10 W, 13 W, 15 W and 18 W output
- Selectable 4000 K, 4500 K and 5000 K colour temperature
- Provides up to 3 hours of emergency illumination after mains failure
- LiFePO4 emergency battery with manual test function
- IP65 protection against dust and water ingress
- IK08 impact resistance for demanding commercial environments
- Maintained and non-maintained emergency operation
- Flicker-free LED output with 120° beam angle
- Surface or suspended mounting options
- Long projected LED life exceeding 102,000 hours at L70
- HACCP-approved DURA G2 platform
- Installation, electrical connection, testing and commissioning should be performed by a licensed electrician in accordance with the manufacturer's instructions, AS/NZS 3000 and applicable emergency-lighting requirements. Emergency systems must be tested and maintained in accordance with AS/NZS 2293.
- Emergency lighting for enclosed car parks and carports
- Warehouses and storage facilities
- Workshops, loading areas and manufacturing facilities
- Public facilities and commercial buildings
- Garages, sheds, balconies and covered outdoor areas
- Temporary installations requiring weatherproof emergency illumination
- AS/NZS 60598.1:2017 including amendments A1 and A2
- AS/NZS 60598.2.1:2014 including amendments A1 and A2
- AS/NZS 60598.2.22:2019 for luminaires for emergency lighting
- AS/NZS 2293.3:2018 including A1 for emergency lighting luminaires
- AS/NZS 61347.1:2016 including A1 and R1
- AS/NZS 61347.2.13:2018 including A1
- AS CISPR 15:2017 for radio disturbance characteristics of lighting equipment
- LED technology provides lower energy consumption than conventional fluorescent battens
- Selectable wattage allows output to be matched to application requirements, helping avoid unnecessary energy use
- Long projected service life can reduce replacement frequency and material waste
- LiFePO4 battery chemistry supports rechargeable emergency operation
- Polycarbonate body and diffuser materials can be separated for appropriate recycling at end of service life
Five-year direct replacement warranty for the luminaire, excluding the emergency battery, subject to Haneco warranty terms and licensed installation requirements.
Available through Haneco and authorised Australian electrical wholesalers and distributors.