First Flush Diversion Controller Matelec
Matelec controller features first flush diversion and tank fill control. Ideal for rainwater harvesting and tank management.
Sign in
Please login to continue to your account.
Alternatively Known As: Matelec FPC-11004, First Flush Diversion Controller, Tank Fill Diversion Controller, Rainwater Diversion Valve Controller
- Model: FPC-11004
- Enclosure Rating: IP56
- Enclosure Material: Powder-coated mild steel with removable gland plate
- Power Supply: 230 VAC single phase
- Float Switch Input: Digital 24 VAC input
- Rain Sensor Input: Digital 24 VDC input
- Valve Output: Air actuator valve control
- Compressor Connection: Weatherproof GPO for air compressor
- Overload Rating: Maximum 6 A
- Included Accessory: 9006 float switch with 10 m cable
- Status Indication: Power on, tank full, valve open and valve closed
- Dimensions (H x L x W): 300mm x 300mm x 150mm
- Weight: 5.5 kg
- Detects rain events and diverts initial contaminated runoff before tank collection
- Provides automatic tank fill control and closes the valve when the tank reaches high level
- Controls an air-actuated diversion valve
- IP56-rated enclosure for outdoor water-management installations
- Padlockable mains isolator for improved service safety
- Low-voltage control and input circuitry
- DIN rail-mounted terminal connections
- Optional battery backup for mains power failure
- Optional special-purpose outlet for automatic pump connection
- Installation and mains electrical connection should be performed by a licensed electrician in accordance with AS/NZS 3000 and the manufacturer's instructions. The controller may also require connection to a suitably installed air-actuated valve, compressor and rain sensor.
- Roof runoff first-flush diversion for rainwater harvesting systems
- Commercial and industrial rainwater tank management
- Diversion of contaminated car park runoff to treatment or stormwater
- Automatic tank filling and overfill prevention
- Stormwater and water-reuse control systems
- AS/NZS 3000:2018 Electrical installations — Wiring Rules
- AS/NZS 3100 Electrical equipment safety requirements, as identified by MATelec for its control solution products
- AS/NZS 61439.1 Low-voltage switchgear and controlgear assemblies, where applicable to the control-panel assembly
- Diverts debris and contaminants from the initial rainwater runoff before water enters the storage tank
- Supports rainwater harvesting and reduces reliance on mains water for suitable applications
- Enables reuse of collected rainwater for irrigation and other non-potable purposes
- Durable steel enclosure can support a long service life and reduce replacement waste
- Steel enclosure components are recyclable at end of service life
12-month standard warranty against defects in materials and workmanship from the date of dispatch, subject to MATelec's warranty conditions and qualified installation requirements.
Available through MATelec Australia and authorised Australian electrical, water-management and irrigation distributors.