FLEXI LOOP Safety Device | SIL 3 & Category 4 | Dual-Channel OSSD Outputs | IP65/IP67 Enclosure | by SICK
The FLEXI LOOP Safety Device is engineered for industrial safety monitoring and control, featuring a SIL 3 safety integrity level and Category 4 compliance. With dual-channel OSSD outputs and robust IP65/IP67 enclosure, it ensures reliable performance in harsh environments, making it ideal for machine safety systems and integration with Flexi Soft safety controllers.
Sign in
Please login to continue to your account.
Alternatively Known As: Flexi Loop Safety Device, FLN OSSD 1100108, SICK Safety Loop Module
- Safety integrity level: SIL 3 (IEC 61508)
- Category: Category 4 (EN ISO 13849)
- Performance level: PL e (EN ISO 13849)
- Mean probability of dangerous failure per hour (PFHD): 0.76 x 10^-9
- Mission time: 20 years
- Connection types: Female M12 8-pin for safety device, Male M12 5-pin for Flexi Loop input, Female M12 5-pin for Flexi Loop output
- Number of non-safe inputs: 1
- Number of non-safe outputs: 1
- Power supply output for external devices: 24 V DC, ≤ 2 A
- Operating voltage: 24 V DC (16.8 V DC to 30 V DC)
- Power consumption: 45 mA
- Input voltage for OSSD inputs: HIGH 13 V DC to 30 V DC, LOW -5 V DC to 5 V DC
- Output type: Highside driver, short-circuit protected
- Output current: ≤ 500 mA
- Protection class: III (EN 61140)
- Enclosure rating: IP65 and IP67 (EN 60529)
- Operating temperature range: -25 °C to +55 °C
- Storage temperature range: -25 °C to +70 °C
- Dimensions (H x L x W): 48mm x 18mm x 68mm
- Weight: 0.1 kg
- Safety integrity level SIL 3 (IEC 61508)
- Category 4 (EN ISO 13849) and Performance level PL e (EN ISO 13849)
- Diagnostic and monitoring functions including cross-circuit, short-circuit, discrepancy and sequence error monitoring
- Dual-channel OSSD outputs for safety sensor connection
- Power supply output for external devices
- Robust IP65 and IP67 enclosure rating for harsh environments
- Wide ambient operating temperature range from -25 °C to +55 °C
- Installation should be performed by qualified personnel familiar with safety systems and electrical standards to ensure compliance and optimal performance.
- Industrial safety monitoring and control
- Machine safety systems requiring dual-channel OSSD outputs
- Integration with Flexi Soft safety controllers
- AS/NZS 4801 – Occupational Health & Safety Management Systems
- Enhances machine safety reducing risk of accidents and associated environmental hazards
- Durable IP65/IP67 rated enclosure reduces need for frequent replacements
Standard manufacturer warranty applies; please refer to SICK for specific warranty terms.
The SICK FLN-OSSD1100108 FLEXI LOOP safety device is available for immediate purchase, ideal for industrial safety and machine control applications.
