FLEXI LOOP Safety Device | SIL 3 & Category 4 | Dual-Channel OSSD Outputs | IP65/IP67 Enclosure | by SICK

BRAND: SICK
SKU: 1061710
$270.80 List price: $340.30
+
The FLEXI LOOP Safety Device is engineered for industrial safety monitoring and control, featuring a SIL 3 safety integrity level and Category 4 compliance. With dual-channel OSSD outputs and robust IP65/IP67 enclosure, it ensures reliable performance in harsh environments, making it ideal for machine safety systems and integration with Flexi Soft safety controllers.

Alternatively Known As: Flexi Loop Safety Device, FLN OSSD 1100108, SICK Safety Loop Module

Technical Specifications
  • Safety integrity level: SIL 3 (IEC 61508)
  • Category: Category 4 (EN ISO 13849)
  • Performance level: PL e (EN ISO 13849)
  • Mean probability of dangerous failure per hour (PFHD): 0.76 x 10^-9
  • Mission time: 20 years
  • Connection types: Female M12 8-pin for safety device, Male M12 5-pin for Flexi Loop input, Female M12 5-pin for Flexi Loop output
  • Number of non-safe inputs: 1
  • Number of non-safe outputs: 1
  • Power supply output for external devices: 24 V DC, ≤ 2 A
  • Operating voltage: 24 V DC (16.8 V DC to 30 V DC)
  • Power consumption: 45 mA
  • Input voltage for OSSD inputs: HIGH 13 V DC to 30 V DC, LOW -5 V DC to 5 V DC
  • Output type: Highside driver, short-circuit protected
  • Output current: ≤ 500 mA
  • Protection class: III (EN 61140)
  • Enclosure rating: IP65 and IP67 (EN 60529)
  • Operating temperature range: -25 °C to +55 °C
  • Storage temperature range: -25 °C to +70 °C
  • Dimensions (H x L x W): 48mm x 18mm x 68mm
  • Weight: 0.1 kg
Key Features
  • Safety integrity level SIL 3 (IEC 61508)
  • Category 4 (EN ISO 13849) and Performance level PL e (EN ISO 13849)
  • Diagnostic and monitoring functions including cross-circuit, short-circuit, discrepancy and sequence error monitoring
  • Dual-channel OSSD outputs for safety sensor connection
  • Power supply output for external devices
  • Robust IP65 and IP67 enclosure rating for harsh environments
  • Wide ambient operating temperature range from -25 °C to +55 °C
Professional Installation Requirements
  • Installation should be performed by qualified personnel familiar with safety systems and electrical standards to ensure compliance and optimal performance.
Applications
  • Industrial safety monitoring and control
  • Machine safety systems requiring dual-channel OSSD outputs
  • Integration with Flexi Soft safety controllers
Standards & Compliance
  • AS/NZS 4801 – Occupational Health & Safety Management Systems
Environmental Benefits
  • Enhances machine safety reducing risk of accidents and associated environmental hazards
  • Durable IP65/IP67 rated enclosure reduces need for frequent replacements
Warranty Information

Standard manufacturer warranty applies; please refer to SICK for specific warranty terms.