The FLEXISOFT CONTROLLER FX3-CPU000000 is designed for industrial safety control applications, featuring a SIL 3 safety integrity level and an IP20 enclosure rating. With a supply voltage of 24V DC and a long mission time of 20 years, this controller ensures high reliability and performance in safety-critical environments. Ideal for machine safety monitoring and integration into safety-related control systems.
Sign in
Please login to continue to your account.
Alternatively Known As: Flexi Soft CPU Module, Safety Controller FX3 CPU, Industrial Safety Controller Module
- Safety integrity level: SIL 3 (IEC 61508)
- Category: Category 4 (EN ISO 13849)
- Performance level: PL e (EN ISO 13849)
- PFHD: 1.07 x 10^-9 (EN ISO 13849)
- Mission time: 20 years (EN ISO 13849)
- System connection: System plug (ordered separately)
- Number of EFI interfaces: 0
- Connection type: Plug-in spring terminals
- Configuration and diagnostics interface: RS-232 (M8 female connector, 4-pin)
- Protection class: III (EN 61140)
- Voltage supply type: PELV or SELV
- Supply voltage: 24 V DC (16.8 V DC to 30 V DC)
- Internal power consumption: ≤ 2.5 W
- Overvoltage category: II (EN 61131-2)
- Switch-on time: ≤ 18 s
- Enclosure rating: IP20 (EN 60529)
- Operating temperature: -25 °C to +55 °C
- Storage temperature: -25 °C to +70 °C
- Air humidity: ≤ 95 %, non-condensing
- Dimensions (H x L x W): 96.5mm x 120.6mm x 22.5mm
- Weight: 0.111 kg
- Main module for Flexi Soft safety controller system
- Configuration via Flexi Soft Designer or Safe EFI-pro System software
- Safety integrity level SIL 3 (IEC 61508)
- Category 4 (EN ISO 13849) with Performance Level PL e
- Mean probability of dangerous failure per hour (PFHD) 1.07 x 10^-9
- Mission time of 20 years
- RS-232 configuration and diagnostics interface with M8 female connector
- Plug-in spring terminal connection type
- Supply voltage 24 V DC (16.8 V DC to 30 V DC)
- Internal power consumption ≤ 2.5 W
- Overvoltage category II (EN 61131-2)
- Switch-on time ≤ 18 seconds
- Protection class III (EN 61140)
- Enclosure rating IP20 (EN 60529)
- Operating temperature range -25 °C to +55 °C
- Storage temperature range -25 °C to +70 °C
- Non-condensing air humidity up to 95%
- Installation and configuration should be performed by qualified personnel familiar with safety control systems and relevant standards to ensure compliance and safety.
- Safety control in industrial automation systems
- Machine safety monitoring and control
- Integration in safety-related control systems
- AS/NZS 4801 – Occupational Health & Safety Management Systems
- Low power consumption of ≤ 2.5 W reduces energy usage
- Long mission time of 20 years supports sustainable operation
- Compliance with RoHS and other environmental standards
Warranty details available upon request from SICK; typically includes coverage against manufacturing defects.
The SICK FX3-CPU000000 FLEXISOFT CONTROLLER is available for immediate purchase, ideal for industrial safety control applications requiring high integrity and reliability.