The High Resolution Rotary Encoder ARS60 offers an impressive 32,767 steps per revolution and a robust blind hollow shaft design with a 15 mm diameter. Ideal for industrial automation and robotics, this encoder features an IP66 enclosure for superior protection against dust and water, ensuring reliable performance in demanding environments.
Sign in
Please login to continue to your account.
Product Name/Title: High Resolution Rotary Encoder ARS60 | 32,767 Steps/Rev | IP66 Enclosure | by SICK
Brand: SICK
SKU: 1032598
Alternatively Known As: Rotary Encoder ARS60, High Resolution Rotary Encoder, SICK Encoder ARS60, Blind Hollow Shaft Encoder
- Resolution: 32,767 steps per revolution
- Measuring step deviation: 0.016°
- Error limits G: 0.046°
- Repeatability standard deviation σr: 0.005°
- Communication interface: SSI with Gray code
- Initialization time: 80 ms
- Supply voltage: 10 to 32 V
- Operating current: typically 60 mA
- Connection type: 11-wire cable, axial, 1.5 m length
- Mechanical design: Blind hollow shaft with 15 mm diameter
- Housing material: Aluminum die cast
- Start-up torque: 0.6 Ncm
- Operating torque: 0.4 Ncm
- Permissible static movement: ±0.3 mm radial, ±0.5 mm axial
- Permissible dynamic movement: ±0.1 mm radial, ±0.2 mm axial
- Operating speed: up to 3,000 min⁻¹
- Bearing lifetime: 3.6 x 10⁹ revolutions
- Operating temperature range: -20 °C to +85 °C
- Enclosure rating: IP66
- Shock resistance: 50 g, 11 ms
- Vibration resistance: 20 g, 10 Hz to 2,000 Hz
- Dimensions (H x L x W): 60mm x 60mm x 60mm
- Weight: 0.3 kg
- High resolution with up to 32,767 steps per revolution
- Blind hollow shaft mechanical design with 15 mm shaft diameter
- Robust aluminum die cast housing with IP66 enclosure rating
- Low start-up torque (0.6 Ncm) and operating torque (0.4 Ncm)
- High resistance to shocks (50 g) and vibration (20 g)
- Operating temperature range from -20 °C to +85 °C
- Communication via SSI interface with Gray code
- Mean time to dangerous failure (MTTFD) of 300 years according to EN ISO 13849-1
- Installation should be performed by qualified personnel familiar with rotary encoders and electrical safety standards to ensure proper connection and calibration.
- Industrial automation and control systems
- Robotics and motion control
- Precision measurement in manufacturing
- Safety-related applications requiring high reliability
- AS/NZS 4801 – Occupational Health & Safety Management Systems
- Durable design reduces need for frequent replacements, minimizing waste
- Energy-efficient operation with low operating current (typ. 60 mA)
Standard manufacturer warranty applies; please refer to SICK's official warranty policy for details.