Ledfire Emergency Luminaire DALI IP44 Rated Black Ektor
Ektor Ledfire Emergency Luminaire DALI features 2100m power rating. Ideal for commercial and public buildings requiring emergency lightin.
Sign in
Please login to continue to your account.
Alternatively Known As: Emergency LED Luminaire, DALI Emergency Light, Recessed Emergency Light, Wireless Emergency Luminaire
- IP Rating: IP44 front face only
- Body Material: Polycarbonate
- Installation Type: Recessed
- Input Voltage: 230Vac (216Vac - 253Vac range)
- Input Frequency: 50 Hz
- Maximum Wattage: 2.5 W
- Standby Power: 0.25 W
- Driver Type: DALI DT1 Emergency and Wireless IEC62386-104 with DT1
- Emergency Mode: Non-Maintained
- Emergency Classification: C0:D63, C90:D63
- Emergency Output Power: 2100 mW
- Emergency Duration: 90 minutes
- Emergency Lumen Output: 330 lumens
- Replacement Battery Code: 01302
- Operating Temperature Range: 0 to 40 °C
- Dimmable: No
- Dimensions (H x L x W): 80mm x 150mm x 150mm
- Weight: 1.2 kg
- IP44 rated front face for moisture protection
- Polycarbonate body for durability
- Recessed installation type
- Non-maintained emergency mode with 90 minutes duration
- DALI DT1 and wireless IEC62386-104 emergency control and monitoring
- Emergency output power of 2100 mW with 330 lumens output
- Supports emergency test and monitoring over DALI and wireless protocols
- Standby power consumption of 0.25 W
- Operating temperature range from 0 to 40 °C
- Maximum wattage of 2.5 W
- Professional installation by a qualified electrician is required to ensure compliance with electrical and safety standards and proper integration with DALI emergency systems.
- Commercial and public buildings requiring emergency lighting
- Recessed installation in ceilings for emergency illumination
- Areas requiring DALI monitored emergency lighting systems
- AS/NZS 60598.1 – Luminaires General Requirements
- AS 60598.2.22 – Emergency Luminaires
- AS/NZS 61347.1 – Lamp Control Gear General and Safety Requirements
- AS/NZS 61347.2.13 – Particular Requirements for Emergency Lighting
- AS CISPR 15 – Limits and Methods of Measurement of Radio Disturbance
- AS/NZS 2293.3 – Emergency Escape Lighting and Exit Signs
- Low standby power consumption reduces energy waste
- Long product design life of 8 years minimizes replacement frequency and waste
- Energy-efficient LED technology reduces overall power usage
6 years return to base warranty for commercial use.
The Ektor Ledfire Advanced Emergency Luminaire DALI is available for immediate purchase, ideal for commercial and public building emergency lighting applications.