Ledfire Pro Emergency Luminaire IP44 Rated Wireless DT1 Ektor
Ektor Ledfire Pro Emergency Luminaire features 1200mm length and 2900m power rating.
Sign in
Please login to continue to your account.
Alternatively Known As: Emergency LED Luminaire, Wireless Emergency Light, Recessed Emergency Light, Ledfire Pro Emergency Light
- IP Rating: IP44 front face only
- Body Material: Polycarbonate
- Installation Type: Recessed
- Working Temperature Range: 0 to 40 °C
- Input Frequency: 50 Hz
- Input Voltage: 230Vac (-6%/+10%)
- Maximum Wattage: 2.5 W
- Standby Power: 0.25 W
- LED Wattage: 4.3 W
- Driver Type: Wireless IEC62386-104 with DALI DT1 emergency
- Dimmable: No
- Flex & Plug Length: 1200 mm
- Wiring Type: Re-wireable Flex & Plug (2 pin)
- Emergency Mode: Non-Maintained
- Emergency Classification: C0:D80, C90:D80
- Emergency Output Power: 2900 mW
- Emergency Duration: 90 minutes
- Emergency Lumen Output: 320 lm or 380 lm depending on model
- Emergency Control: Wireless DALI Monitored IEC62386-104
- Product Design Life: 12 years
- Dimensions (H x L x W): 80mm x 150mm x 150mm
- Weight: 1.2 kg
- IP44 rated front face for protection against splashing water
- Polycarbonate body for durability
- Recessed installation type
- Wireless IEC62386-104 compliant DALI DT1 emergency driver included
- Non-dimmable
- Emergency duration of 90 minutes
- Emergency output power of 2900 mW
- Emergency lumen output of 320 lm or 380 lm depending on model
- Supports wireless test and monitoring over IEC62386-104
- Product design life of 12 years
- Professional installation by a qualified electrician is required to ensure compliance with electrical and safety standards.
- Commercial and public buildings emergency lighting
- Recessed installation in ceilings for emergency escape routes
- Non-maintained emergency lighting applications
- AS/NZS 60598.1 – Luminaires General Requirements
- AS 60598.2.22 – Emergency Lighting Luminaires
- AS/NZS 61347.1 – Lamp Control Gear General and Safety Requirements
- AS/NZS 61347.2.13 – Particular Requirements for Emergency Lighting Control Gear
- AS CISPR 15 – Limits and Methods of Measurement of Radio Disturbance Characteristics of Electrical Lighting and Similar Equipment
- AS/NZS 2293.3 – Emergency Escape Lighting and Exit Signs for Buildings
- Low power consumption with 2.5 W maximum wattage
- Long product design life reduces waste and replacement frequency
- Wireless monitoring reduces need for manual testing, saving energy and resources
8 years return to base warranty for commercial use.
The Ektor Ledfire Pro Emergency Luminaire - D80 is available for immediate purchase, ideal for commercial and public building emergency lighting applications.