Lock Electro Mechanical Safety Lock IP67 Rated i10 e0454 SICK
SICK Lock Electro Mechanical Safety Lock features 1m current and 20.4V operating voltage.
Sign in
Please login to continue to your account.
- Sensor principle: Electro-mechanical
- Locking principle: Power to lock
- Positive action N/C solenoid monitoring contacts: 2
- Positive action N/C door monitoring contacts: 1
- Locking force Fmax: 1,300 N (EN ISO 14119)
- Locking force FZh: 1,000 N (EN ISO 14119)
- Actuation force: ≥ 10 N
- Retaining force: ≤ 20 N
- Actuation frequency: ≤ 1,200 per hour
- Actuation directions: 4
- Approach speed: ≤ 20 m/min
- B10d parameter: 3 x 10^6 switching cycles (small load)
- Type: Type 2 (EN ISO 14119)
- Actuator coding level: Low coding level (EN ISO 14119)
- Safe state in fault: No internal fault detection; fault detection by connected safety logic unit
- Safe series connection: With Flexi Loop (with diagnostics)
- Connection type: Plug connector, M12, 8-pin
- Coupling nut material: Brass
- Contamination rating: 3
- Switching principle: Slow action switching element
- Usage category: AC-15/DC-13 (IEC 60947-5-1)
- Rated operating current: 1 A (24 V AC/DC)
- Rated insulation voltage Ui: 30 V
- Rated impulse withstand voltage Uimp: 1,500 V AC
- Type of output: Electro-mechanical contacts
- Power consumption: ≤ 8 W
- Short-circuit protection: 1 A gG
- Switching voltage: ≥ 12 V DC
- Switching current: 1 mA (24 V DC)
- Solenoid operating voltage: 20.4 V DC to 26.4 V DC
- Switch-on time of magnet: 100%
- Mechanical life: 1 x 10^6 switching cycles
- Housing material: Glass-fiber reinforced thermoplastic
- Enclosure rating: IP67 (IEC 60529)
- Ambient operating temperature: –20 °C to +55 °C
- Storage temperature: –20 °C to +55 °C
- Dimensions (H x L x W): 120mm x 40mm x 60mm
- Weight: 0.5 kg
- Electro-mechanical sensor principle with power to lock mechanism
- Positive action N/C solenoid monitoring contacts: 2
- Positive action N/C door monitoring contacts: 1
- Locking force up to 1,300 N compliant with EN ISO 14119
- Actuation force ≥ 10 N with 4 actuation directions
- Safe series connection with Flexi Loop diagnostics
- IP67 rated enclosure for protection against dust and water
- Operating temperature range from –20 °C to +55 °C
- Plug connector M12, 8-pin with brass coupling nut
- Installation must be performed by qualified personnel familiar with safety interlock systems and electrical connections to ensure compliance with safety standards.
- Industrial safety interlocking for machinery and access control
- Safety door locking in automated production lines
- Use in hazardous areas requiring secure locking and monitoring
- AS/NZS 4801 – Occupational Health & Safety Management Systems
- Durable construction reduces replacement frequency and waste
- Low power consumption (≤ 8 W) supports energy efficiency
Standard manufacturer warranty applies. Please refer to SICK's official warranty policy for details.
The SICK i10-E0454 Lock is available for immediate purchase, ideal for industrial safety and access control applications.