Manual Motor Starter 48-65A 1NO 1NC Aux 80A Frame NS2 Chint
Chint NS2 manual motor starter features 48-65A thermal overload, 1NO+1NC aux contact, magnetic short-circuit trip, and rotary control. Ideal for DOL motor starting.
Sign in
Please login to continue to your account.
Alternatively Known As: Motor Protection Circuit Breaker, Manual Motor Starter, Motor Protective Switch, DOL Motor Starter
- Product Series: NS2-80
- Adjustment Range: 48–65A
- Frame Rating: 80A
- Auxiliary Contacts: 1NO+1NC side-mounted auxiliary contact
- Poles: 3P
- Rated Insulation Voltage Ui: 690V
- Rated Operating Voltage Ue: Up to AC690V
- Rated Frequency: 50/60Hz
- Application Category: AC-3
- Trip Class: Class 10 thermal overload protection
- Rated Ultimate Short-Circuit Breaking Capacity Icu: 50kA
- Rated Service Short-Circuit Breaking Capacity Ics: 17.5kA
- Instantaneous Magnetic Trip Setting: 910A
- Rated Impulse Withstand Voltage Uimp: 8kV
- Terminal Conductor Capacity: 2.5–25mm²
- Terminal Screw Size: M8
- Terminal Tightening Torque: 6N·m
- Operating Frequency: Up to 25 operations per hour
- Control Type: Rotary handle with manual reset
- Dimensions (H x L x W): 118.4mm x 119.5mm x 63.6mm
- Weight: 0.98 kg
- Adjustable thermal overload protection from 48A to 65A
- Magnetic protection against motor short circuits
- Phase-failure protection for three-phase motors
- Integrated 1NO+1NC auxiliary contact for control and status signalling
- Suitable for direct-on-line motor starting applications
- High 50kA ultimate short-circuit breaking capacity
- Compatible with selected CHINT NS2 accessories, including undervoltage and shunt releases
- Suitable for use with compatible CHINT NC1 and NC8 contactors
- Installation and electrical connection should be performed by a licensed electrician in accordance with the manufacturer's instructions, AS/NZS 3000 and applicable electrical safety requirements. Confirm short-circuit protection, motor full-load current and enclosure suitability before commissioning.
- Direct-on-line starting and protection of three-phase motors
- Commercial and industrial motor control panels
- Pumps, fans, compressors and other fixed motor loads
- Motor overload, phase-loss and short-circuit protection
- Manual motor isolation and local rotary control
- AS/NZS 60947.2 and AS/NZS 60947.4.1 are the applicable Australian/New Zealand product-standard adoptions for low-voltage circuit-breaker and motor-starter equipment; verify local approval and RCM requirements before installation
- Motor overload and phase-loss protection can help prevent premature motor failure and reduce replacement waste
- Supports efficient motor-system operation by protecting motors from damaging overload conditions
- Durable low-voltage switchgear construction can provide extended service life when correctly installed and maintained
- Electrical components should be recovered and recycled through appropriate e-waste channels at end of life
CHINT's general warranty policy states 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels. Contractual terms or Australian distributor conditions may vary.
Available through authorised CHINT distributors in Australia.