Manual Motor Starter 48-65A 80A Frame NS2 Chint
Chint NS2 manual motor starter features 48-65A thermal overload, magnetic short-circuit trip, and rotary control. Ideal for DOL motor starting.
Sign in
Please login to continue to your account.
Alternatively Known As: Motor Protection Circuit Breaker, Manual Motor Protector, DOL Motor Starter, Motor Overload and Short-Circuit Protector
- Frame Rating: 80A
- Adjustable Thermal Overload Range: 48–65A
- Rated Continuous Current: 65A
- Number of Poles: 3
- Rated Insulation Voltage Ui: 690V
- Rated Operating Voltage Ue: 230–690V AC
- Rated Frequency: 50/60Hz
- Utilisation Category: AC-3
- Trip Class: 10A
- Instantaneous Magnetic Trip: 910A
- Rated Ultimate Short-Circuit Capacity: 50kA at 400/415V AC
- Terminal Screw Size: M8
- Compatible Conductor Size: 2.5–25mm²
- Protection Degree: IP20
- Ambient Operating Temperature: −5°C to +40°C
- Mounting: Fixed installation; maximum inclination 5° from vertical
- Dimensions (H x L x W): 118.4mm x 119.5mm x 63.6mm
- Weight: 0.93 kg
- Adjustable thermal overload protection from 48A to 65A
- Magnetic instantaneous protection against short circuits
- Phase-failure protection for three-phase motors
- Rotary manual start and stop control
- Suitable for direct-on-line motor starting applications
- Can be combined with compatible CHINT contactors and auxiliary accessories
- Designed for motor protection and infrequent switching duties
- Installation, wiring and commissioning should be carried out by a licensed electrician in accordance with AS/NZS 3000 and the manufacturer's instructions. Select suitable upstream short-circuit protection and verify the motor full-load current before adjustment.
- Direct-on-line starting of three-phase motors
- HVAC and refrigeration plant
- Fans, pumps and compressors
- Industrial machinery and process equipment
- Motor control panels and switchboards
- Product design is based on IEC/EN 60947-2 and IEC/EN 60947-4-1 requirements
- Installation in Australia should be assessed and completed in accordance with AS/NZS 3000
- Integrated overload, short-circuit and phase-failure protection can help prevent motor damage and reduce premature equipment replacement
- Durable switchgear construction supports extended service life and reduced replacement waste
- Compatible replaceable accessories can extend the useful life of the motor protection assembly
CHINT's general warranty policy specifies 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to contract terms. Local Australian end-user warranty conditions may differ.
Available through authorised CHINT distributors in Australia.