MCCB 3P 1000A 50kA Basic Electronic 1600A Frame NM8N Chint
Chint NM8N 1000A 3P MCCB features 50kA breaking capacity, basic electronic trip unit and a 1600A frame. Ideal for switchboard mains and sub-mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N 1600 Frame MCCB, 3-Pole Moulded Case Circuit Breaker, Electronic Trip MCCB, 1000A 50kA Circuit Breaker
- Breaker Type: Moulded case circuit breaker
- Series: NM8N-1600
- Poles: 3P
- Rated Current: 1000A
- Frame Size: 1600A
- Trip Unit: Basic electronic type EN
- Breaking Capacity: 50kA, S-class
- Rated Operational Voltage: Up to 690V AC, 50/60Hz
- Rated Insulation Voltage: 1000V
- Rated Impulse Withstand Voltage: 8kV
- Overload Protection: Adjustable electronic long-time current setting
- Short-Circuit Protection: Adjustable short-time and instantaneous electronic protection
- Connection Type: Front connection, fixed manual type
- Operating Temperature: -40°C to +70°C, subject to current derating
- Dimensions (H x L x W): 286mm x 167mm x 210mm
- Weight: 13.5 kg
- 1600A frame with a 1000A rated current
- Three-pole configuration for three-phase distribution systems
- 50kA short-circuit breaking capacity
- Basic electronic trip unit for adjustable overcurrent protection
- Suitable for switchboard mains and sub-mains protection
- Supports protection against overload and short-circuit faults
- Designed for AC systems up to 690V
- Compact moulded-case construction for low-voltage power distribution
- Installation, selection, protection-setting adjustment and commissioning must be performed by a licensed electrician or suitably qualified electrical contractor in accordance with the approved switchboard design, manufacturer instructions and applicable Australian wiring requirements.
- Main incoming protection in commercial and industrial switchboards
- Sub-main circuit protection
- Low-voltage three-phase power distribution
- Commercial building electrical infrastructure
- Industrial plant and machinery distribution circuits
- Generator, transformer and utility distribution protection
- AS/NZS IEC 60947.2:2015 is the applicable Australian/New Zealand product standard for low-voltage circuit-breakers; verify project-specific certification and RCM requirements before installation.
- AS/NZS 3000:2018 applies to selection and installation within Australian electrical installations.
- Moulded-case construction provides an extended service life, reducing replacement frequency and electrical equipment waste.
- Copper and metal components can be recovered for recycling at end of service life.
- Electronic protection enables accurate current settings, which can help reduce nuisance tripping and unnecessary equipment replacement.
- RoHS and environmental compliance should be confirmed against the supplied product certification for the specific market variant.
CHINT general warranty policy for other low-voltage apparatus is 27 months from the date of manufacture when purchased through authorised sales channels; contractual or Australian distributor terms may vary.
Available through authorised CHINT distributors in Australia.