MCCB 3P 100A 100kA Magnetic Only 125A Frame NM8N Chint
Chint NM8N 100A 3P MCCB features 100kA breaking capacity, magnetic-only trip unit for motor protection and a 125A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-125H M 100 3P MCCB, Magnetic Motor Protection Circuit Breaker, 125A Frame MCCB
- Rated Current: 100 A
- Number of Poles: 3P
- Frame Size: 125 A
- Breaking Capacity: 100 kA at 380/400/415 V AC
- Release Type: Magnetic-only electromagnetic release
- Magnetic Trip Setting: 12 x In for 63–100 A models, ±20% accuracy
- Rated Operational Voltage: 380/415 V AC
- Maximum Operational Voltage: 690 V AC
- Rated Insulation Voltage: 1000 V AC
- Rated Impulse Withstand Voltage: 8 kV
- Utilisation Category: Category A
- Ingress Protection: IP00, or IP40 with terminal covers
- Reference Standard: IEC/EN 60947-2
- Dimensions (H x L x W): 140mm x 90mm x 78.5mm
- Weight: 1.05 kg
- 100 kA short-circuit breaking capacity at 380/400/415 V AC
- Magnetic-only release designed for short-circuit protection in motor circuits
- 125 A frame with 100 A rated current
- Three-pole configuration for three-phase systems
- Suitable for switchboard, power centre and motor control centre applications
- Compatible with the NM8N range of auxiliary and functional accessories
- Suitable for isolation when installed in accordance with the applicable requirements
- Installation, testing and commissioning must be performed by a licensed electrical contractor in accordance with AS/NZS 3000, applicable switchboard requirements and the manufacturer's instructions. Magnetic-only protection does not provide motor overload protection; a suitably coordinated thermal overload relay is required for motor applications.
- Three-phase motor short-circuit protection
- Switchboard mains and feeder protection
- Industrial power distribution boards
- Power centres and motor control centres
- Commercial and industrial low-voltage electrical installations
- Designed to IEC/EN 60947-2 requirements for low-voltage circuit-breakers
- AS/NZS IEC 60947.2 is the applicable Australian/New Zealand product standard for moulded-case circuit-breakers
- Installation should comply with AS/NZS 3000 and the applicable AS/NZS 61439 switchboard requirements
- RoHS declaration is available for the NM8N product family, supporting restriction of hazardous substances
- Durable moulded-case construction and high mechanical life can reduce replacement frequency and associated waste
- Copper and metallic components can be recovered for recycling at end of service life
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to the applicable sales contract and warranty conditions.
Available through authorised CHINT distributors in Australia.