MCCB 3P 160A 150kA Magnetic Only 250A Frame NM8N Chint
Chint NM8N 160A 3P MCCB features 150kA breaking capacity, magnetic-only trip unit for motor protection and a 250A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-250R-M 160A 3P MCCB, Motor Protection MCCB, Magnetic-Only Moulded Case Circuit Breaker
- Breaker Type: Moulded case circuit breaker
- Frame Size: 250A frame
- Rated Current: 160A
- Number of Poles: 3P
- Trip Unit: Magnetic-only motor protection
- Breaking Capacity: 150kA Icu at AC 380–415V
- Rated Working Voltage: 380–415VAC
- Rated Voltage: Up to 690VAC
- Frequency: 50/60Hz
- Magnetic Trip Setting: 9–14 times rated current for motor protection
- Utilisation Category: A
- Standard: IEC/EN 60947-2
- Mechanical Life: 25,000 operating cycles
- Electrical Life: 10,000 operating cycles at AC 415V
- Dimensions (H x L x W): 157mm x 88.7mm x 105mm
- Weight: 1.85 kg
- High 150kA short-circuit breaking capacity
- Magnetic-only trip unit designed for motor protection applications
- Compact 250A frame with a 160A rated current
- Three-pole configuration for three-phase systems
- Suitable for switchboard mains, feeders and motor circuits
- Front, rear and DIN-rail mounting options available within the NM8N range
- Positive isolation and manual switching capability
- Installation, selection and commissioning must be performed by a licensed electrician. A magnetic-only breaker does not provide overload protection, so a correctly selected motor overload relay or equivalent protection is required where applicable. Install and verify settings in accordance with AS/NZS 3000, the manufacturer’s instructions and the switchboard design.
- Three-phase motor short-circuit protection
- Motor control centres and industrial control panels
- Switchboard mains and submain protection
- High-fault-level commercial and industrial distribution systems
- Feeder protection where magnetic-only tripping is required
- AS/NZS IEC 60947.2: Applicable Australian/New Zealand product standard for low-voltage circuit-breakers
- AS/NZS 3000: Applicable wiring and installation requirements; final compliance depends on the complete installation and local approval requirements
- Long mechanical and electrical service life can reduce replacement frequency and associated waste
- Metal and thermoplastic components may be recoverable through appropriate electrical equipment recycling streams
- Supports reliable motor and distribution protection, helping reduce damage-related equipment replacement
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus, including MCCBs, when purchased through authorised sales channels; contract terms may vary.
Available through authorised CHINT distributors in Australia.