MCCB 3P 160A 150kA Standard Electronic 250A Frame NM8N Chint
Chint NM8N 160A 3P MCCB features 150kA breaking capacity, standard electronic trip unit and a 250A frame. Ideal for switchboard mains and sub-mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: NM8N-250R EM 160A 3P MCCB, Electronic Moulded Case Circuit Breaker, 160 Amp 150kA MCCB
- Product Type: Moulded case circuit breaker
- Rated Current: 160A
- Frame Size: 250A
- Number of Poles: 3P
- Breaking Capacity: 150kA at 380–415VAC
- Trip Unit: Standard electronic EM type with adjustable protection
- Rated Operational Voltage: Up to 690VAC
- Rated Insulation Voltage: 1,000V
- Rated Frequency: 50/60Hz
- Utilisation Category: A
- Ingress Protection: IP40
- Mechanical Endurance: 15,000 operating cycles
- Electrical Endurance: 6,000 operating cycles
- Connection: Fixed front or rear connection options
- Installation Orientation: Vertical or horizontal mounting
- Dimensions (H x L x W): 157mm x 88.7mm x 105mm
- Weight: 1.85 kg
- High 150kA short-circuit breaking capacity at 380–415VAC
- Standard electronic trip unit for accurate and adjustable overcurrent protection
- 250A frame accommodates a 160A rated current
- Three-pole configuration for three-phase distribution systems
- Suitable for switchboard mains and sub-mains protection
- Supports overload, short-circuit and undervoltage protection functions
- Suitable for isolation when installed in accordance with the manufacturer’s instructions
- Top or bottom line entry and flexible mounting options
- Installation, testing and commissioning must be carried out by a licensed electrical contractor in accordance with AS/NZS 3000, the manufacturer’s instructions and applicable switchboard requirements. Verify fault levels, discrimination, cable ratings and protection settings before energisation.
- Switchboard mains protection
- Sub-main protection
- Commercial building distribution boards
- Industrial power distribution systems
- Data centre and critical power distribution
- Motor and equipment feeder protection
- Low-voltage electrical installations requiring high fault-current interruption
- AS/NZS IEC 60947.2:2015 for low-voltage circuit-breakers
- AS/NZS 3000 for electrical installation and wiring requirements
- Durable construction and long mechanical service life can reduce replacement frequency and material waste
- Metal components can be recovered for recycling at end of service life
- Electronic protection supports accurate fault clearing and appropriate protection coordination, helping reduce equipment damage and replacement waste
CHINT’s general policy for other low-voltage apparatus provides 27 months from the date of manufacture against defects in materials and workmanship when supplied through authorised sales channels; contract terms may vary.
Available through authorised CHINT distributors in Australia.