MCCB 3P 16A 36kA Magnetic Only 125A Frame NM8N Chint
Chint NM8N 16A 3P MCCB features 36kA breaking capacity, magnetic-only trip unit for motor protection and a 125A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: Magnetic MCCB, Motor Protection MCCB, Moulded Case Circuit Breaker, 3-Phase Motor Circuit Breaker
- Rated Current: 16 A
- Number of Poles: 3P
- Frame Size: 125 A
- Trip Unit: Magnetic-only motor protection
- Ultimate Breaking Capacity: 36 kA at 380–440 V AC
- Service Breaking Capacity: 36 kA at 380–440 V AC
- Rated Operational Voltage: Up to 690 V AC
- Rated Insulation Voltage: 1,000 V
- Rated Impulse Withstand Voltage: 8 kV
- Rated Frequency: 50/60 Hz
- Utilisation Category: A
- Ingress Protection: IP40
- Mechanical Life: 15,000 operating cycles
- Electrical Life: Up to 8,000 operating cycles at 415 V AC
- Ambient Operating Temperature: -40°C to +70°C
- Installation: Fixed front connection, vertical or horizontal mounting
- Dimensions (H x L x W): 140mm x 78.5mm x 90mm
- Weight: 1.19 kg
- Magnetic-only trip unit designed for motor protection applications
- High 36 kA short-circuit breaking capacity at typical three-phase supply voltages
- Compact 125A frame with a 16A rated current
- Suitable for low-voltage AC distribution and motor circuits
- Supports vertical or horizontal installation
- Top or bottom line connection options
- Isolation function suitable for approved applications
- IP40 enclosure protection under specified installation conditions
- Installation and commissioning must be carried out by a licensed electrical contractor in accordance with the manufacturer's instructions, applicable switchboard requirements and AS/NZS 3000. Correct coordination with the motor starter, overload protection, cabling and prospective fault current is required.
- Motor short-circuit protection
- Industrial control panels and motor control centres
- Commercial and industrial switchboards
- Low-voltage three-phase distribution boards
- Protection of motor feeders where overload protection is provided separately
- Main or sub-main protection where the 16A magnetic-only characteristic is suitable
- IEC/EN 60947-2 for moulded-case circuit breakers
- AS/NZS IEC 60947.2:2020 is the applicable Australian/New Zealand adoption for low-voltage circuit breakers where required by the installation or procurement specification
- AS/NZS 3000 applies to electrical installation, wiring and switchboard integration
- Long mechanical service life can reduce replacement frequency and associated waste
- Metal terminals and internal conductive components can be recovered through appropriate electrical equipment recycling
- Provides durable fault protection that can help prevent damage to connected motors and switchboard equipment
CHINT general warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to the applicable sales contract and warranty conditions.
Available through authorised CHINT distributors in Australia.