MCCB 3P 180A 100kA Magnetic Only 250A Frame NM8N Chint
Chint NM8N 180A 3P MCCB features 100kA breaking capacity, magnetic-only trip unit for motor protection and a 250A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: Moulded Case Circuit Breaker, MCCB, Motor Protection MCCB, Magnetic-Only Circuit Breaker, NM8N-250H
- Product Series: NM8N-250H
- Number of Poles: 3P
- Rated Current: 180A
- Frame Size: 250A
- Trip Unit: Magnetic-only motor protection type M
- Rated Ultimate Breaking Capacity Icu: 100kA at 380/400/415V AC
- Rated Service Breaking Capacity Ics: 100kA at 380/400/415V AC
- Rated Operational Voltage: Up to 690V AC, 50/60Hz
- Rated Insulation Voltage Ui: 1000V AC
- Rated Impulse Withstand Voltage Uimp: 8kV
- Utilisation Category: A
- Mounting: Fixed or DIN rail mounting options
- Connection: Front or rear connection options
- Isolation Function: Suitable for isolation
- Magnetic Trip Setting: 9–14 times rated current for motor protection
- External Overload Protection: Required where overload protection is not provided elsewhere
- Dimensions (H x L x W): 157mm x 88.7mm x 105mm
- Weight: 1.85 kg
- 100kA short-circuit breaking capacity at 380/400/415V AC
- Magnetic-only trip unit designed for motor circuit short-circuit protection
- 250A frame accepts a rated current of 180A
- Three-pole configuration for three-phase systems
- Suitable for switchboard mains and industrial power distribution applications
- High 1000V insulation rating and 8kV impulse withstand rating
- Compatible with fixed, DIN rail, front-connection and rear-connection arrangements
- Suitable for isolation when installed in an appropriate system
- Separate overload protection should be provided for motor applications
- Installation, selection and commissioning must be performed by a licensed electrician in accordance with applicable wiring rules, manufacturer instructions and coordinated motor protection requirements. Verify fault levels, cable ratings, discrimination and any required external overload protection before installation.
- Switchboard mains protection
- Three-phase motor circuit short-circuit protection
- Industrial power distribution boards
- Commercial electrical distribution systems
- Motor control centres and feeder protection
- Low-voltage systems requiring high fault-current withstand capacity
- AS/NZS IEC 60947.2 for low-voltage circuit-breakers
- AS/NZS 3000 may apply to the electrical installation, wiring and switchboard installation
- Durable moulded-case construction can support long service life and reduce replacement waste
- Metal terminals and conductive components are recyclable through appropriate electrical recycling streams
- High breaking capacity can help limit fault damage to associated equipment and reduce unnecessary component replacement
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to applicable contract terms and conditions.
Available through authorised CHINT distributors in Australia.