MCCB 3P 180A 150kA Magnetic Only 250A Frame NM8N Chint
Chint NM8N 180A 3P MCCB features 150kA breaking capacity, magnetic-only trip unit for motor protection and a 250A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N 250R M 180A 3P MCCB, Magnetic Motor Protection Circuit Breaker, Moulded Case Circuit Breaker
- Product Type: Moulded case circuit breaker
- Frame Size: 250A
- Rated Current: 180A at 40°C
- Number of Poles: 3P
- Trip Unit: Magnetic-only electromagnetic release
- Breaking Capacity: 150kA at 380/400/415V AC
- Breaking Capacity: 100kA at 440V AC; 50kA at 500V AC; 10kA at 660/690V AC
- Service Breaking Capacity: Equal to ultimate breaking capacity at the stated voltages
- Rated Operational Voltage: 380/400/415V, 440V, 500V, 660/690V AC, 50/60Hz
- Rated Insulation Voltage: 1000V AC
- Rated Impulse Withstand Voltage: 8kV
- Magnetic Trip Adjustment: 9–14 times rated current for motor protection
- Installation: Fixed mounting; suitable for vertical or horizontal installation
- Line Entry: Top or bottom line entry
- Mechanical Durability: Up to 15,000 operating cycles
- Electrical Durability: Up to 1,500 operating cycles
- Dimensions (H x L x W): 157mm x 88.7mm x 105mm
- Weight: 1.85 kg
- 150kA short-circuit breaking capacity at 380/400/415V AC
- Magnetic-only trip unit designed for motor starting applications
- 250A frame with an 180A rated current
- Three-pole configuration for three-phase systems
- Adjustable magnetic trip range of 9–14 times rated current for motor protection
- Suitable for switchboard mains, motor feeders and industrial distribution systems
- Optional auxiliary, shunt, undervoltage, motor-operation and rotary-handle accessories are available
- Installation, commissioning and adjustment must be performed by a licensed electrician in accordance with applicable Australian electrical requirements. The magnetic-only trip unit provides short-circuit protection and should be coordinated with a separate overload or thermal relay for motor protection. Installation and switchboard assembly should be assessed against AS/NZS 3000 and AS/NZS 61439 where applicable.
- Three-phase motor short-circuit protection
- Industrial motor control assemblies using a separate overload relay
- Switchboard mains and sub-mains protection
- Commercial and industrial power distribution
- High prospective-fault-current installations
- Applicable product standard: AS/NZS IEC 60947-2 for low-voltage circuit-breakers
- The NM8N series is specified by CHINT to IEC 60947-1 and IEC 60947-2; Australian installation compliance must be verified for the completed assembly
- Long operating life can reduce replacement frequency and electrical-equipment waste
- Metallic and polymer components can be directed to appropriate electrical-equipment recycling streams at end of service life
- Magnetic-only construction avoids the additional thermal trip element used in thermal-magnetic variants
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to applicable contract terms and warranty conditions.
Available through authorised CHINT distributors in Australia.