MCCB 3P 180A 50kA Magnetic Only 250A Frame NM8N Chint
Chint NM8N 180A 3P MCCB features 50kA breaking capacity, magnetic-only trip unit for motor protection and a 250A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-250S 180A 3P MCCB, magnetic circuit breaker, motor protection MCCB, moulded case circuit breaker
- Product Type: Moulded case circuit breaker
- Frame Size: 250A
- Rated Current: 180A
- Number of Poles: 3P
- Trip Unit: Magnetic-only release for motor protection
- Rated Ultimate Short-Circuit Breaking Capacity Icu: 50kA at 380/400/415V AC
- Rated Service Short-Circuit Breaking Capacity Ics: 50kA at 380/400/415V AC
- Rated Operational Voltage: Up to 690V AC, 50/60Hz
- Rated Insulation Voltage Ui: 1000V
- Rated Impulse Withstand Voltage Uimp: 8kV
- Utilisation Category: A
- Isolation Suitability: Suitable for isolation
- Installation: Fixed or DIN rail mounting with front or rear connection
- Mechanical Endurance: 25,000 operating cycles
- Electrical Endurance: 10,000 operating cycles at 415V AC and rated current
- Manufacturer Standard: IEC/EN 60947-2
- Dimensions (H x L x W): 157mm x 88.7mm x 105mm
- Weight: 1.85 kg
- Three-pole configuration for three-phase circuits
- 50kA high short-circuit breaking capacity at 415V AC
- Magnetic-only trip unit suited to motor-starting applications
- 180A rated current in a 250A frame
- Suitable for switchboard mains and industrial power distribution protection
- Compact fixed-mount MCCB with front or rear connection options
- Suitable for AC systems up to 690V
- Zero arcing distance design
- Installation, selection and adjustment should be performed by a licensed electrical contractor in accordance with AS/NZS 3000, the manufacturer's instructions and the requirements of the switchboard assembly. Confirm prospective fault current, cable ratings, discrimination and motor starting characteristics before commissioning.
- Motor circuit short-circuit protection
- Industrial switchboards
- Commercial building power distribution
- Three-phase mains and feeder protection
- Manufacturing machinery and motor control panels
- Data centre and infrastructure electrical distribution
- AS/NZS IEC 60947.2 for low-voltage circuit breakers, subject to verification of the specific Australian-market product documentation
- AS/NZS 3000 for electrical installation and switchboard wiring requirements
- Copper and other metallic components can be recovered and recycled at end of service life
- Long mechanical and electrical endurance can reduce replacement frequency and associated waste
- RoHS documentation is available for the NM8N product series
- Supports reliable electrical distribution and motor protection, helping reduce damage-related equipment waste
CHINT's general policy specifies a 27-month warranty from the date of manufacture for other low-voltage apparatus sold through authorised channels, subject to contract terms, correct installation and operating conditions.
Available through authorised CHINT distributors in Australia.