- Rated Current: 180 A at 40°C
- Number of Poles: 3P
- Frame Size: 250 A
- Release Type: Adjustable thermal-magnetic trip unit
- Breaking Capacity: 50 kA at 380/400/415 V AC
- Rated Operational Voltage: Up to 690 V AC, 50/60 Hz
- Rated Insulation Voltage: 1,000 V
- Rated Impulse Withstand Voltage: 8 kV
- Thermal Overload Adjustment: 0.7–1.0 x In
- Magnetic Short-Circuit Adjustment: 5–10 x In for distribution protection
- Utilisation Category: A
- Mechanical Durability: 15,000 operating cycles
- Electrical Durability: 1,500 operating cycles
- Connection Type: Fixed front or rear connection options
- Standard Product Reference: IEC 60947-2
- Dimensions (H x L x W): 232mm x 88mm x 105mm
- Weight: 1.85 kg
- 50 kA short-circuit breaking capacity for high-fault-level distribution systems
- Adjustable thermal protection from 0.7 to 1.0 times the rated current
- Adjustable instantaneous magnetic protection for short-circuit events
- Three-pole configuration for three-phase circuit protection
- 250 A frame accommodates rated current settings from 125 to 250 A
- Suitable for manual isolation and low-voltage power distribution
- Compact moulded-case construction for switchboard installation
- Installation, configuration and connection should be performed by a licensed electrician in accordance with AS/NZS 3000, the manufacturer's instructions and applicable electrical safety requirements. Correct fault-current coordination, cable sizing and tightening torque must be verified before energisation.
- Switchboard mains protection
- Sub-main and feeder protection
- Commercial and industrial low-voltage distribution
- Three-phase plant and equipment protection
- Power distribution circuits requiring adjustable overload and short-circuit protection
- AS/NZS IEC 60947.2:2015 is the applicable Australian/New Zealand standard for low-voltage circuit-breakers; verify current certification and RCM requirements for the specific supply model before installation
- AS/NZS 3000 applies to selection, wiring and installation within Australian electrical installations
- Durable moulded-case construction can reduce replacement frequency and associated material waste
- Metallic conductors and components may be recoverable through appropriate electrical equipment recycling streams
- Adjustable protection settings support accurate circuit protection and can help prevent equipment damage and premature replacement
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised sales channels, subject to the applicable contract and warranty conditions.
Available through authorised CHINT distributors in Australia.