MCCB 3P 250A 150kA Thermal Magnetic 400A Frame NM8N Chint
Chint NM8N 250A 3P MCCB features 150kA breaking capacity, thermal-magnetic trip unit and a 400A frame. Ideal for switchboard mains and sub-mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N 400R MCCB, 250A Thermal-Magnetic Circuit Breaker, 3-Phase Moulded Case Circuit Breaker
- Rated Current: 250 A
- Number of Poles: 3P
- Frame Size: 400 A
- Trip Unit: Thermal-magnetic, adjustable
- Ultimate Short-Circuit Breaking Capacity Icu: 150 kA at 380/400/415 V AC
- Service Short-Circuit Breaking Capacity Ics: 150 kA at 380/400/415 V AC
- Rated Operational Voltage: 380/400/415, 440, 500, 660/690 V AC, 50/60 Hz
- Breaking Capacity at 440 V AC: 100 kA
- Breaking Capacity at 500/525 V AC: 50 kA
- Breaking Capacity at 660/690 V AC: 15 kA
- Rated Insulation Voltage Ui: 1000 V
- Rated Impulse Withstand Voltage Uimp: 12 kV
- Utilisation Category: A
- Installation: Fixed mounting with front or rear connection options
- Dimensions (H x L x W): 255mm x 140mm x 113mm
- Weight: 5.2 kg
- 150 kA high fault-current interruption at 380/400/415 V AC
- Thermal-magnetic overload and short-circuit protection
- Adjustable thermal and magnetic trip settings
- Three-pole construction for three-phase distribution circuits
- 400A frame accommodates 250A rated current
- Suitable for switchboard mains, sub-mains and industrial distribution protection
- Zero arcing distance design
- Mechanical service life of up to 15,000 operating cycles
- Installation, selection and commissioning should be performed by a licensed electrician in accordance with the manufacturer's instructions, applicable switchboard requirements and AS/NZS 3000. Confirm fault level, discrimination, cable capacity and enclosure suitability before installation.
- Switchboard mains protection
- Sub-mains and feeder protection
- Commercial and industrial power distribution
- Three-phase electrical equipment protection
- High fault-level low-voltage distribution systems
- Relevant Australian/New Zealand product standard: AS/NZS IEC 60947.2:2015, Low-voltage switchgear and controlgear, Part 2: Circuit-breakers
- Manufacturer performance and testing references IEC/EN 60947-2
- Durable moulded-case construction supports a long service life and reduces replacement waste
- Resettable circuit protection avoids routine fuse replacement and associated consumable waste
- Suitable for use in efficient, maintainable low-voltage power distribution systems
CHINT's general warranty policy covers other low-voltage apparatus against defects in materials and workmanship for 27 months from the date of manufacture when supplied through authorised sales channels. Contract-specific conditions may apply.
Available through authorised CHINT distributors in Australia.