MCCB 3P 250A 50kA Magnetic Only 250A Frame NM8N Chint
Chint NM8N 250A 3P MCCB features 50kA breaking capacity, magnetic-only trip unit for motor protection and a 250A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-250S M 250 3P MCCB, Magnetic-Only Moulded Case Circuit Breaker, Motor Protection MCCB
- Product Type: Moulded case circuit breaker
- Rated Current: 250A
- Frame Size: 250A
- Number of Poles: 3P
- Release Type: Magnetic-only instantaneous release
- Magnetic Trip Setting: 9–14 x In, approximately 2,250–3,500A
- Rated Operational Voltage: 380/400/415V AC, 440V AC, 500V AC and 660/690V AC
- Rated Insulation Voltage: 1,000V AC
- Rated Impulse Withstand Voltage: 8kV
- Ultimate Breaking Capacity Icu: 50kA at 380/400/415V AC
- Service Breaking Capacity Ics: 50kA at 380/400/415V AC
- Rated Frequency: 50/60Hz
- Utilisation Category: A
- Mechanical Life: 25,000 operations
- Electrical Life: 10,000 operations at 415V AC and 2,000 operations at 690V AC
- Connection Type: Fixed, front or rear connection options
- Dimensions (H x L x W): 157mm x 105mm x 89mm
- Weight: 2 kg
- Magnetic-only trip unit for short-circuit protection
- Suitable for motor protection when used with a contactor and thermal overload relay
- 50kA breaking capacity at common low-voltage supply ratings
- Adjustable instantaneous magnetic trip setting from 9 to 14 times rated current
- Three-pole construction for three-phase switchboards
- Compatible with optional auxiliary, shunt-trip, undervoltage and mechanical accessories
- Designed for industrial and commercial low-voltage power distribution
- Installation, connection and testing must be carried out by a licensed electrician in accordance with manufacturer instructions, AS/NZS 3000 and applicable switchboard requirements. A separate thermal overload relay is required for motor overload protection because this model has magnetic-only protection.
- Three-phase switchboard mains protection
- Motor short-circuit protection with a contactor and thermal overload relay
- Industrial and commercial low-voltage power distribution
- Feeders, incomers and high-current distribution circuits
- AS/NZS IEC 60947.2:2015 for low-voltage circuit-breakers
- AS/NZS 3000:2018 applies to installation within Australian electrical installations
- Long mechanical and electrical service life can reduce replacement frequency and associated material waste
- Metal and thermoplastic components may be recoverable for recycling at end of service life, subject to local recycling facilities
- Magnetic-only construction avoids the additional thermal sensing components used in thermal-magnetic trip units
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels; contract and regional warranty terms may vary.
Available through authorised CHINT distributors in Australia.