MCCB 3P 250A 50kA Thermal Magnetic 250A Frame NM8N Chint
Chint NM8N 250A 3P MCCB features 50kA breaking capacity, thermal-magnetic trip unit and a 250A frame. Ideal for switchboard mains and sub-mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-250S TM 250 3P MCCB, moulded case circuit breaker, 250A 3-phase circuit breaker
- Frame Size: 250A
- Rated Current: 250A
- Number of Poles: 3P
- Trip Unit: Adjustable thermal-magnetic
- Breaking Capacity: 50kA Icu and Ics at 380/400/415V AC
- Breaking Capacity at 500V AC: 40kA
- Breaking Capacity at 660/690V AC: 8kA
- Rated Operational Voltage: 380/400/415V, 440V, 500V, 660/690V AC
- Rated Insulation Voltage: 1000V AC
- Rated Impulse Withstand Voltage: 8kV
- Thermal Adjustment Range: 0.7–1.0 x In, equivalent to 175–250A
- Magnetic Adjustment Range: 5–10 x In for 180–250A power-distribution ratings
- Rated Frequency: 50/60Hz
- Mechanical Durability: 15,000 operations
- Electrical Durability: 1,500 operations
- Dimensions (H x L x W): 200mm x 120mm x 106mm
- Weight: 1.75 kg
- Three-pole moulded case circuit breaker for low-voltage AC distribution
- Adjustable thermal protection for overload conditions
- Adjustable magnetic protection for short-circuit conditions
- 250A frame with 250A rated current
- 50kA short-circuit breaking capacity at common 400/415V system voltages
- Suitable for switchboard mains and sub-mains protection
- Compatible with optional auxiliary, shunt-trip, undervoltage and operating-mechanism accessories
- Installation, testing and commissioning must be performed by a licensed electrician in accordance with applicable wiring rules, switchboard requirements and the manufacturer's instructions. Confirm fault levels, discrimination, cable capacity and local RCM requirements before energising.
- Switchboard main incomer protection
- Sub-main circuit protection
- Commercial and industrial power distribution
- Protection of feeders and distribution boards
- Overload and short-circuit protection for three-phase AC circuits
- AS/NZS IEC 60947.2: applicable standard for low-voltage circuit-breakers and MCCBs
- IEC/EN 60947-2 product standard reference
- Long mechanical and electrical service life can reduce replacement frequency and product waste
- Metallic conductive components and moulded enclosure materials can be separated for recycling at end of service life
- Thermal-magnetic operation requires no electronic trip-unit power supply during normal protection operation
CHINT warranty policy provides 27 months from the date of manufacture for other low-voltage apparatus sold through authorised channels, unless the customer contract specifies different terms. Warranty is subject to the manufacturer's conditions.
Available through authorised CHINT distributors in Australia.