MCCB 3P 250A 70kA Magnetic Only 250A Frame NM8N Chint
Chint NM8N 250A 3P MCCB features 70kA breaking capacity, magnetic-only trip unit for motor protection and a 250A frame. Ideal for switchboard mains protection.
Sign in
Please login to continue to your account.
Alternatively Known As: CHINT NM8N-250H M 250 3P MCCB, Magnetic MCCB, Motor Protection MCCB, Moulded Case Circuit Breaker
- Product Type: Moulded case circuit breaker
- Number of Poles: 3P
- Frame Size: 250A
- Rated Current: 250A
- Release Type: Magnetic-only release for motor protection
- Breaking Capacity: 70kA at AC 380/400/415V
- Rated Operational Voltage: Up to 690V AC, 50/60Hz
- Rated Insulation Voltage Ui: 1000V
- Rated Impulse Withstand Voltage Uimp: 8kV
- Utilisation Category: A
- Suitable for Isolation: Yes
- Mechanical Life: 25,000 operations
- Electrical Life: 10,000 operations at AC 415V and rated current
- Ambient Temperature: -40°C to +70°C
- Mounting: Fixed installation
- Product Standard: IEC/EN 60947-2
- Dimensions (H x L x W): 157mm x 88.7mm x 105mm
- Weight: 1.85 kg
- Magnetic-only trip unit designed for motor protection applications
- High 70kA short-circuit breaking capacity at 380/400/415V AC
- 250A frame with 250A rated current
- Three-pole configuration for three-phase systems
- Suitable for switchboard mains and industrial power distribution
- Can be used for isolation when installed in accordance with system requirements
- Compact 250-frame construction with front connection options
- Installation, selection and adjustment should be performed by a licensed electrician in accordance with AS/NZS 3000, the switchboard manufacturer's requirements and applicable electrical regulations. Magnetic-only protection does not provide thermal overload protection, so the complete motor protection arrangement must be correctly designed.
- Switchboard mains protection
- Three-phase industrial power distribution
- Motor feeder short-circuit protection
- Commercial and industrial electrical installations
- Power distribution equipment requiring high fault-level protection
- IEC/EN 60947-2 manufacturer-declared product standard
- AS/NZS IEC 60947.2 is the applicable Australian/New Zealand standard for low-voltage circuit breakers; verify local conformity and RCM requirements before installation
- AS/NZS 3000 applies to selection and installation within Australian electrical installations
- Durable construction and long mechanical life can reduce replacement frequency and associated material waste
- Metallic and thermoplastic components can be separated for recycling at end of service life where suitable recycling facilities are available
- Efficient fault interruption helps limit equipment damage and reduce replacement of downstream switchboard components
CHINT warranty policy generally provides 27 months from the date of manufacture for other low-voltage apparatus when purchased through authorised sales channels, subject to the applicable contract and warranty conditions.
Available through authorised CHINT distributors in Australia.